<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>ScholarWorks Community:</title>
  <link rel="alternate" href="https://scholar.korea.ac.kr/handle/2021.sw.korea/2547" />
  <subtitle />
  <id>https://scholar.korea.ac.kr/handle/2021.sw.korea/2547</id>
  <updated>2026-04-09T14:33:49Z</updated>
  <dc:date>2026-04-09T14:33:49Z</dc:date>
  <entry>
    <title>Monte Carlo simulation study of an &amp;lt;i&amp;gt;in vivo&amp;lt;/i&amp;gt; four-dimensional tracking system with a diverging collimator for monitoring radiation source (Ir-192) location during brachytherapy: proof of concept and feasibility</title>
    <link rel="alternate" href="https://scholar.korea.ac.kr/handle/2021.sw.korea/197513" />
    <author>
      <name>Oh, Geon</name>
    </author>
    <author>
      <name>Lee, Jeongshim</name>
    </author>
    <author>
      <name>Kim, Hunjung</name>
    </author>
    <author>
      <name>Kim, Woochul</name>
    </author>
    <author>
      <name>Kang, Sangwon</name>
    </author>
    <author>
      <name>Chung, Jinbeom</name>
    </author>
    <author>
      <name>Jeong, Seonghoon</name>
    </author>
    <author>
      <name>Lee, Hakjae</name>
    </author>
    <author>
      <name>Yoon, Myonggeun</name>
    </author>
    <author>
      <name>Lee, Boram</name>
    </author>
    <id>https://scholar.korea.ac.kr/handle/2021.sw.korea/197513</id>
    <updated>2024-11-19T00:47:41Z</updated>
    <published>2024-03-25T00:00:00Z</published>
    <summary type="text">Title: Monte Carlo simulation study of an &amp;lt;i&amp;gt;in vivo&amp;lt;/i&amp;gt; four-dimensional tracking system with a diverging collimator for monitoring radiation source (Ir-192) location during brachytherapy: proof of concept and feasibility
Authors: Oh, Geon; Lee, Jeongshim; Kim, Hunjung; Kim, Woochul; Kang, Sangwon; Chung, Jinbeom; Jeong, Seonghoon; Lee, Hakjae; Yoon, Myonggeun; Lee, Boram
Abstract: Introduction: The aim of this study was to demonstrate the potential of an in vivo four-dimensional (4D) tracking system to accurately localize the radiation source, Iridium-192 (Ir-192) in high-dose rate brachytherapy. Methods: To achieve time-dependent 3D positioning of the Ir-192 source, we devised a 4D tracking system employing multiple compact detectors. During the system&amp;apos;s design phase, we conducted comprehensive optimization and analytical evaluations of the diverging collimator employed for detection purposes. Subsequently, we executed 3D reconstruction and positioning procedures based on the 2D images obtained by six detectors, each equipped with an optimized diverging collimator. All simulations for designing and evaluating the 4D tracking system were performed using the open-source GATE (v9.1) Monte Carlo platform based on the GEANT4 (v10.7) toolkit. In addition, to evaluate the accuracy of the proposed 4D tracking system, we conducted simulations and 3D positioning using a solid phantom and patient data. Finally, the error between the reconstructed position coordinates determined by the tracking system and the original coordinates of the Ir-192 radiation source was analyzed. Results: The parameters for the optimized diverging collimator were a septal thickness of 0.3 mm and a collimator height of 30 mm. A tracking system comprising 6 compact detectors was designed and implemented utilizing this collimator. Analysis of the accuracy of the proposed Ir-192 source tracking system found that the average of the absolute values of the error between the 3D reconstructed and original positions for the simulation with the solid phantom were 0.440 mm for the x coordinate, 0.423 mm for the y coordinate, and 0.764 mm for the z coordinate, and the average Euclidean distance was 1.146 mm. Finally, in a simulation based on data from a patient who underwent brachytherapy, the average Euclidean distance between the original and reconstructed source position was 0.586 mm. Discussion: These results indicated that the newly designed in vivo 4D tracking system for monitoring the Ir-192 source during brachytherapy could determine the 3D position of the radiation source in real time during treatment. We conclude that the proposed positioning system has the potential to make brachytherapy more accurate and reliable.</summary>
    <dc:date>2024-03-25T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Study of multistep Dense U-Net-based automatic segmentation for head MRI scans</title>
    <link rel="alternate" href="https://scholar.korea.ac.kr/handle/2021.sw.korea/197728" />
    <author>
      <name>Gi, Yongha</name>
    </author>
    <author>
      <name>Oh, Geon</name>
    </author>
    <author>
      <name>Jo, Yunhui</name>
    </author>
    <author>
      <name>Lim, Hyeongjin</name>
    </author>
    <author>
      <name>Ko, Yousun</name>
    </author>
    <author>
      <name>Hong, Jinyoung</name>
    </author>
    <author>
      <name>Lee, Eunjun</name>
    </author>
    <author>
      <name>Park, Sangmin</name>
    </author>
    <author>
      <name>Kwak, Taemin</name>
    </author>
    <author>
      <name>Kim, Sangcheol</name>
    </author>
    <author>
      <name>Yoon, Myonggeun</name>
    </author>
    <id>https://scholar.korea.ac.kr/handle/2021.sw.korea/197728</id>
    <updated>2024-11-19T00:51:14Z</updated>
    <published>2023-11-13T00:00:00Z</published>
    <summary type="text">Title: Study of multistep Dense U-Net-based automatic segmentation for head MRI scans
Authors: Gi, Yongha; Oh, Geon; Jo, Yunhui; Lim, Hyeongjin; Ko, Yousun; Hong, Jinyoung; Lee, Eunjun; Park, Sangmin; Kwak, Taemin; Kim, Sangcheol; Yoon, Myonggeun
Abstract: BackgroundDespite extensive efforts to obtain accurate segmentation of magnetic resonance imaging (MRI) scans of a head, it remains challenging primarily due to variations in intensity distribution, which depend on the equipment and parameters used.PurposeThe goal of this study is to evaluate the effectiveness of an automatic segmentation method for head MRI scans using a multistep Dense U-Net (MDU-Net) architecture.MethodsThe MDU-Net-based method comprises two steps. The first step is to segment the scalp, skull, and whole brain from head MRI scans using a convolutional neural network (CNN). In the first step, a hybrid network is used to combine 2.5D Dense U-Net and 3D Dense U-Net structure. This hybrid network acquires logits in three orthogonal planes (axial, coronal, and sagittal) using 2.5D Dense U-Nets and fuses them by averaging. The resultant fused probability map with head MRI scans then serves as the input to a 3D Dense U-Net. In this process, different ratios of active contour loss and focal loss are applied. The second step is to segment the cerebrospinal fluid (CSF), white matter, and gray matter from extracted brain MRI scans using CNNs. In the second step, the histogram of the extracted brain MRI scans is standardized and then a 2.5D Dense U-Net is used to further segment the brain&amp;apos;s specific tissues using the focal loss. A dataset of 100 head MRI scans from an OASIS-3 dataset was used for training, internal validation, and testing, with ratios of 80%, 10%, and 10%, respectively. Using the proposed approach, we segmented the head MRI scans into five areas (scalp, skull, CSF, white matter, and gray matter) and evaluated the segmentation results using the Dice similarity coefficient (DSC) score, Hausdorff distance (HD), and the average symmetric surface distance (ASSD) as evaluation metrics. We compared these results with those obtained using the Res-U-Net, Dense U-Net, U-Net++, Swin-Unet, and H-Dense U-Net models.ResultsThe MDU-Net model showed DSC values of 0.933, 0.830, 0.833, 0.953, and 0.917 in the scalp, skull, CSF, white matter, and gray matter, respectively. The corresponding HD values were 2.37, 2.89, 2.13, 1.52, and 1.53 mm, respectively. The ASSD values were 0.50, 1.63, 1.28, 0.26, and 0.27 mm, respectively. Comparing these results with other models revealed that the MDU-Net model demonstrated the best performance in terms of the DSC values for the scalp, CSF, white matter, and gray matter. When compared with the H-Dense U-Net model, which showed the highest performance among the other models, the MDU-Net model showed substantial improvements in the HD view, particularly in the gray matter region, with a difference of approximately 9%. In addition, in terms of the ASSD, the MDU-Net model outperformed the H-Dense U-Net model, showing an approximately 7% improvements in the white matter and approximately 9% improvements in the gray matter.ConclusionCompared with existing models in terms of DSC, HD, and ASSD, the proposed MDU-Net model demonstrated the best performance on average and showed its potential to enhance the accuracy of automatic segmentation for head MRI scans.</summary>
    <dc:date>2023-11-13T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Correlation between impulse magnitude and inhibition of cell proliferation in alternating electric fields therapy</title>
    <link rel="alternate" href="https://scholar.korea.ac.kr/handle/2021.sw.korea/192706" />
    <author>
      <name>Oh, Geon</name>
    </author>
    <author>
      <name>Jo, Yunhui</name>
    </author>
    <author>
      <name>Gi, Yongha</name>
    </author>
    <author>
      <name>Hong, Jinyoung</name>
    </author>
    <author>
      <name>Kim, Jonghyun</name>
    </author>
    <author>
      <name>Lee, Boram</name>
    </author>
    <author>
      <name>Yoon, Myonggeun</name>
    </author>
    <id>https://scholar.korea.ac.kr/handle/2021.sw.korea/192706</id>
    <updated>2024-11-18T02:44:37Z</updated>
    <published>2023-08-01T00:00:00Z</published>
    <summary type="text">Title: Correlation between impulse magnitude and inhibition of cell proliferation in alternating electric fields therapy
Authors: Oh, Geon; Jo, Yunhui; Gi, Yongha; Hong, Jinyoung; Kim, Jonghyun; Lee, Boram; Yoon, Myonggeun
Abstract: This study was designed to investigate the correlation between the impulse by dielectrophoretic force applied inside a dividing cell during alternating electric fields therapy and the inhibition of cell proliferation. Distributions of the electric field and dielectrophoretic force inside a dividing cell were calculated using the finite element method of COMSOL Multiphysics. Based on the results, the average magnitude of the impulse by the dielectrophoretic force applied to the cleavage furrow inside a dividing cell placed in various directions was calculated as a function of electric field intensity at an extracellular reference point. The simulation results showed that the average magnitude of the impulse to the cleavage furrow inside a dividing cell ranged from 1.51 x 10(-9) to 1.49 x 10(-7) N s when tumor treating fields with an intensity ranging from 0.1 to 1 V/cm is applied at an extracellular reference point for 6 h. To verify the relationships between the impulse by the dielectrophoretic force and the inhibition of cell proliferation, the survival fractions of the four cancer cell lines were determined as a function of intensity and time duration of the electric field. The correlation between the magnitude and application time of the electric field and the survival fractions of the four cell lines showed similar trends in vitro. These results suggest that both the dielectrophoretic force and the time required for the force to act are proportionally related to the inhibitory effect on dividing cells, enabling this impulse to be used as a reference to quantify the inhibition of cell proliferation.</summary>
    <dc:date>2023-08-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Feasibility study of a scintillation sheet-based detector for fluence monitoring during external photon beam radiotherapy</title>
    <link rel="alternate" href="https://scholar.korea.ac.kr/handle/2021.sw.korea/192693" />
    <author>
      <name>Seo, Jaehyeon</name>
    </author>
    <author>
      <name>Lee, Hyunho</name>
    </author>
    <author>
      <name>Ahn, Sung Hwan</name>
    </author>
    <author>
      <name>Yoon, Myonggeun</name>
    </author>
    <id>https://scholar.korea.ac.kr/handle/2021.sw.korea/192693</id>
    <updated>2024-11-18T02:44:34Z</updated>
    <published>2023-08-01T00:00:00Z</published>
    <summary type="text">Title: Feasibility study of a scintillation sheet-based detector for fluence monitoring during external photon beam radiotherapy
Authors: Seo, Jaehyeon; Lee, Hyunho; Ahn, Sung Hwan; Yoon, Myonggeun
Abstract: Purpose: This study evaluated the properties of a scintillation sheet-based dosimetry system for beam monitoring with high spatial resolution, including the effects of this system on the treatment beam. The dosimetric characteristics and feasibility of this system for clinical use were also evaluated.Methods: The effects of the dosimetry system on the beam were evaluated by measuring the percentage depth doses, dose profiles, and transmission factors. Fifteen treatment plans were created, and the influence of the dosimetry system on these clinical treatment plans was evaluated. The performance of the system was assessed by determining signal linearity, dose rate dependence, and reproducibility. The feasibility of the system for clinical use was evaluated by comparing intensity distributions with reference intensity distributions verified by quality assurance.Results: The spatial resolution of the dosimetry system was found to be 0.43 mm/pixel when projected to the isocenter plane. The dosimetry system attenuated the intensity of 6 MV beams by about 1.1%, without affecting the percentage depth doses and dose profiles. The response of the dosimetry system was linear, independent of the dose rate used in the clinic, and reproducible. Comparison of intensity distributions of evaluation treatment fields with reference intensity distributions showed that the 1%/1 mm average gamma passing rate was 99.6%. Conclusions: The dosimetry system did not significantly alter the beam characteristics, indicating that the system could be implemented by using only a transmission factor. The dosimetry system is clinically suitable for monitoring treatment beam delivery with higher spatial resolution than other transmission detectors.</summary>
    <dc:date>2023-08-01T00:00:00Z</dc:date>
  </entry>
</feed>

