Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Jong-Han-
dc.contributor.authorLim, Chae Seung-
dc.contributor.authorLee, Min-Geol-
dc.contributor.authorKim, Hyon-Suk-
dc.date.accessioned2021-09-05T17:01:47Z-
dc.date.available2021-09-05T17:01:47Z-
dc.date.created2021-06-15-
dc.date.issued2014-
dc.identifier.issn2044-6055-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/101054-
dc.description.abstractObjective: We compared the automated non-treponemal reagin (rapid plasma reagin (RPR)) test with the conventional RPR card test for usefulness in clinical applications. Setting: A comparative study of laboratory methods using clinical specimens in a single institute. Participants: A total of 112 serum samples including 59 Treponema pallidum particle agglutination (TPPA)-positive and 53 TPPA-negative specimens were evaluated. Outcome measures: HiSens Auto RPR LTIA (HBI, Anyang, Korea) was compared with Macro-Vue RPR Card Tests (Becton Dickinson BD Microbiology Systems, Sparks, Maryland, USA). Treponemal-specific tests were performed by Serodia TPPA assay (Fujirebio, Tokyo, Japan). The percentage agreement,. value and overall sensitivity and specificity of the two RPR tests were compared. Seroconversion rates after treatment were also compared for each RPR test. Results: The percentage agreement between the two RPR tests was 78.6% (kappa 0.565; 95% CI 0.422 to 0.709). Sensitivity and specificity of the automated RPR test relative to the TPPA test was 52.5% (95% CI 39.1% to 65.7%) and 94.3% (95% CI 84.3% to 98.8%), respectively, while the same values for the conventional RPR card test were 86.4% (95% CI 75% to 93.9%) and 94.3% (95% CI 84.3% to 98.8%), respectively. The conventional RPR card test showed overall higher positivity than the automated RPR test, whereas the automated RPR test showed higher seroconversion (43.5%, 10/23) than the conventional RPR card test (4.3%, 1/23) in treated patients. Conclusions: The automated RPR test showed overall lower sensitivity than the conventional RPR test based on the treponemal test, but higher seroconversion after treatment. The automated RPR test could be used to monitor treatment response, especially in the reverse screening algorithm in syphilis testing.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMJ PUBLISHING GROUP-
dc.subjectGUIDELINES-
dc.subjectDIAGNOSIS-
dc.titleComparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing-
dc.typeArticle-
dc.contributor.affiliatedAuthorLim, Chae Seung-
dc.identifier.doi10.1136/bmjopen-2014-005664-
dc.identifier.scopusid2-s2.0-84920507213-
dc.identifier.wosid000355413900013-
dc.identifier.bibliographicCitationBMJ OPEN, v.4, no.12-
dc.relation.isPartOfBMJ OPEN-
dc.citation.titleBMJ OPEN-
dc.citation.volume4-
dc.citation.number12-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusGUIDELINES-
dc.subject.keywordPlusDIAGNOSIS-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE