Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Chi Hyun-
dc.contributor.authorKim, Ju Yeon-
dc.contributor.authorNyeck, Agnes E.-
dc.contributor.authorLim, Chae Seung-
dc.contributor.authorHur, Dae Sung-
dc.contributor.authorChung, Chanil-
dc.contributor.authorChang, Jun Keun-
dc.contributor.authorAn, Seong Soo A.-
dc.contributor.authorShin, Sehyun-
dc.date.accessioned2021-09-05T17:03:07Z-
dc.date.available2021-09-05T17:03:07Z-
dc.date.created2021-06-15-
dc.date.issued2014-
dc.identifier.issn1386-0291-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/101063-
dc.description.abstractSince Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.subjectLATEX AGGLUTINATION-
dc.subjectGEL TEST-
dc.subjectANTIGEN-
dc.subjectCOUNTER-
dc.titleMeasurement of RBC agglutination with microscopic cell image analysis in a microchannel chip-
dc.typeArticle-
dc.contributor.affiliatedAuthorCho, Chi Hyun-
dc.contributor.affiliatedAuthorLim, Chae Seung-
dc.contributor.affiliatedAuthorShin, Sehyun-
dc.identifier.doi10.3233/CH-131673-
dc.identifier.scopusid2-s2.0-84895809661-
dc.identifier.wosid000332245300007-
dc.identifier.bibliographicCitationCLINICAL HEMORHEOLOGY AND MICROCIRCULATION, v.56, no.1, pp.67 - 74-
dc.relation.isPartOfCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.citation.titleCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.citation.volume56-
dc.citation.number1-
dc.citation.startPage67-
dc.citation.endPage74-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaHematology-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryHematology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.subject.keywordPlusLATEX AGGLUTINATION-
dc.subject.keywordPlusGEL TEST-
dc.subject.keywordPlusANTIGEN-
dc.subject.keywordPlusCOUNTER-
dc.subject.keywordAuthorAgglutination-
dc.subject.keywordAuthorscoring-
dc.subject.keywordAuthorC-reader-
dc.subject.keywordAuthormicrochannel chip-
dc.subject.keywordAuthorCRAT-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Se hyun photo

Shin, Se hyun
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE