Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Systematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Young Joo-
dc.contributor.authorPark, Seong-Hi-
dc.contributor.authorKang, Chang-Bum-
dc.date.accessioned2021-09-05T18:14:47Z-
dc.date.available2021-09-05T18:14:47Z-
dc.date.created2021-06-15-
dc.date.issued2013-12-
dc.identifier.issn2005-3673-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/101385-
dc.description.abstractPurpose: Infrared thermometers are increasingly used as a convenient, non-invasive assessment method for febrile children. However, the diagnostic accuracy of the infrared thermometer for children has been questioned, particularly in relation to sensitivity and specificity. The aim of this study was to evaluate diagnostic accuracy of infrared thermometers in febrile children. Methods: Articles published between 1966 and 2012 from periodicals indexed in the Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected, using the following keywords: 'infrared thermometer'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Nineteen diagnostic studies with high methodological quality, involving 4,304 children, were included. The results of meta-analysis showed that the pooled sensitivity, specificity and AUC (Area Under the Curve) of infrared tympanic thermometers in children over 1 year were 0.80 (95% Cl 0.78, 0.81), 0.94 (95% Cl 0.93, 0.95) and 0.95 respectively. However the diagnostic accuracy of infrared tympanic thermometers in children with hyperthermia was low. Conclusion: The diagnostic accuracy of infrared tympanic thermometer was similar to axillary and rectal thermometers indicating a need for further research to substantiate these findings in children with hyperthermia.-
dc.languageKorean-
dc.language.isoko-
dc.publisherKOREAN SOC NURSING SCIENCE-
dc.subjectTYMPANIC MEMBRANE TEMPERATURE-
dc.subjectEAR THERMOMETRY-
dc.subjectBODY-TEMPERATURE-
dc.subjectAXILLARY-
dc.subjectRELIABILITY-
dc.titleSystematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Young Joo-
dc.identifier.doi10.4040/jkan.2013.43.6.746-
dc.identifier.scopusid2-s2.0-84893332802-
dc.identifier.wosid000330486200006-
dc.identifier.bibliographicCitationJOURNAL OF KOREAN ACADEMY OF NURSING, v.43, no.6, pp.746 - 759-
dc.relation.isPartOfJOURNAL OF KOREAN ACADEMY OF NURSING-
dc.citation.titleJOURNAL OF KOREAN ACADEMY OF NURSING-
dc.citation.volume43-
dc.citation.number6-
dc.citation.startPage746-
dc.citation.endPage759-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001832641-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNursing-
dc.relation.journalWebOfScienceCategoryNursing-
dc.subject.keywordPlusTYMPANIC MEMBRANE TEMPERATURE-
dc.subject.keywordPlusEAR THERMOMETRY-
dc.subject.keywordPlusBODY-TEMPERATURE-
dc.subject.keywordPlusAXILLARY-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordAuthorThermometer-
dc.subject.keywordAuthorSensitivity-
dc.subject.keywordAuthorSpecificity-
dc.subject.keywordAuthorMeta-analysis-
dc.subject.keywordAuthorChild-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Nursing > Department of Nursing > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE