Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Il-Sik | - |
dc.contributor.author | Baek, Sang-Ho | - |
dc.contributor.author | Kim, Young Ho | - |
dc.date.accessioned | 2021-09-05T19:39:47Z | - |
dc.date.available | 2021-09-05T19:39:47Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2013-11 | - |
dc.identifier.issn | 0003-3219 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/101735 | - |
dc.description.abstract | Objective: To investigate the effects of wobbling angle on the stability measures of orthodontic mini-implants (OMIs) during insertion and removal procedures in artificial bone blocks. Materials and Methods: A total of 36 OMIs (self-drilling type, cylindrical shape, 7 mm in length, 1.45 mm in diameter) were allocated into three groups according to the amount of wobbling angle (W-0 degrees, W-2 degrees, and W-4 degrees groups; N=12 per group). The OMIs were installed and subsequently removed from artificial bone blocks (Sawbone) using a driving torque tester with a uniform speed of 28 rpm. Insertion peak time (IPT), maximum insertion torque (MIT), total insertion energy (TIE), near-peak insertion energy (NPIE), maximum removal torque (MRT), and near-peak removal energy (NPRE) were measured. Results: The W-4 degrees group showed the longest IPT and highest TIE and NPIE, followed by the W-2 degrees and W-0 degrees groups (W-0 degrees < W-2 degrees < W-4 degrees, all P < .001). The W-2 degrees and W-4 degrees groups showed significant increase in MIT compared with the W-0 degrees group (W-0 degrees < [W-4 degrees,W-2 degrees]; P < .001). Although there was no significant difference in NPRE among the three groups, the W-4 degrees group showed a decrease in MRT compared with the W-0 degrees and W-2 degrees groups (W-4 degrees < [W-2 degrees,W-0 degrees]; P < .05). Although the W-4 degrees group showed a 14.5% (2.9 Ncm) increase in MIT compared with the W-0 degrees group, there was only a 6% (1.3 Ncm) decrease in MRT from the W-0 degrees group to the W-4 degrees group. Conclusion: Slight wobbling during the OMI insertion procedure may be acceptable in terms of the stability measures of OMIs during insertion and removal procedures. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | E H ANGLE EDUCATION RESEARCH FOUNDATION, INC | - |
dc.subject | CORTICAL BONE | - |
dc.subject | TORQUE | - |
dc.subject | MINISCREWS | - |
dc.subject | SUCCESS | - |
dc.subject | MICRODAMAGE | - |
dc.subject | DIAMETER | - |
dc.subject | SCREWS | - |
dc.subject | SHAPE | - |
dc.title | Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Cho, Il-Sik | - |
dc.identifier.doi | 10.2319/021513-134.1 | - |
dc.identifier.scopusid | 2-s2.0-84891873416 | - |
dc.identifier.wosid | 000327291300011 | - |
dc.identifier.bibliographicCitation | ANGLE ORTHODONTIST, v.83, no.6, pp.1009 - 1014 | - |
dc.relation.isPartOf | ANGLE ORTHODONTIST | - |
dc.citation.title | ANGLE ORTHODONTIST | - |
dc.citation.volume | 83 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1009 | - |
dc.citation.endPage | 1014 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | CORTICAL BONE | - |
dc.subject.keywordPlus | TORQUE | - |
dc.subject.keywordPlus | MINISCREWS | - |
dc.subject.keywordPlus | SUCCESS | - |
dc.subject.keywordPlus | MICRODAMAGE | - |
dc.subject.keywordPlus | DIAMETER | - |
dc.subject.keywordPlus | SCREWS | - |
dc.subject.keywordPlus | SHAPE | - |
dc.subject.keywordAuthor | Stability measures | - |
dc.subject.keywordAuthor | Orthodontic mini-implants | - |
dc.subject.keywordAuthor | Wobbling | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.