Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of the actual amount of axial movement of 3 aspheric intraocular lenses using anterior segment optical coherence tomography

Full metadata record
DC Field Value Language
dc.contributor.authorEom, Youngsub-
dc.contributor.authorKang, Su-Yeon-
dc.contributor.authorSong, Jong-Suk-
dc.contributor.authorKim, Hyo Myung-
dc.date.accessioned2021-09-05T20:34:32Z-
dc.date.available2021-09-05T20:34:32Z-
dc.date.created2021-06-15-
dc.date.issued2013-10-
dc.identifier.issn0886-3350-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/101975-
dc.description.abstractPURPOSE: To compare the mean effective lens position (ELP) and actual amount of axial movement of 3 aspheric intraocular lenses (IOLs) using anterior segment optical coherence tomography (AS-OCT). SETTING: Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea. DESIGN: Retrospective comparative study. METHODS: Consecutive patients had phacoemulsification with aspheric IOL implantation. The ELP measurements by AS-OCT were taken 1 week and 1, 3, and 6 months postoperatively. The ELPRMS was defined as the root mean square (RMS) of the change in ELP at each follow-up timepoint. RESULTS: An XL Stabi ZO 3-plate IOL was implanted in 30 eyes, an Acrysof IQ C-loop IOL in 22 eyes, and an Akreos MI-60 4-plate IOL in 17 eyes. The 4-plate IOL showed significant changes in the mean ELP from 1 week to 1 month and from 3 to 6 months postoperatively (P=.005 and P=.028, respectively). The changes of the other 2 IOLs were insignificant during the 3 postoperative visits. However, the mean ELPRMS of the C-loop IOL (0.06 mm +/- 0.31 [SD]) was smaller than that of the 3-plate IOL (0.14 +/- 0.28 mm) and the 4-plate IOL (0.20 +/- 0.35 mm) (P=.014 and P=.023, respectively) during the 3 timepoints. CONCLUSION: An appropriate method based on the actual amount of axial IOL movement, such as the ELPRMS, is needed to assess the axial positional stability of IOLs.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectPOLY(METHYL METHACRYLATE)-
dc.subjectCHAMBER DEPTH-
dc.subjectPOSITION-
dc.subjectSILICONE-
dc.subjectCAPSULE-
dc.subjectPOLYMETHYLMETHACRYLATE-
dc.subjectCAPSULORHEXIS-
dc.subjectDECENTRATION-
dc.subjectDESIGN-
dc.subjectERROR-
dc.titleComparison of the actual amount of axial movement of 3 aspheric intraocular lenses using anterior segment optical coherence tomography-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.contributor.affiliatedAuthorSong, Jong-Suk-
dc.contributor.affiliatedAuthorKim, Hyo Myung-
dc.identifier.doi10.1016/j.jcrs.2013.04.040-
dc.identifier.scopusid2-s2.0-84885023046-
dc.identifier.wosid000325909600012-
dc.identifier.bibliographicCitationJOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.39, no.10, pp.1528 - 1533-
dc.relation.isPartOfJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.titleJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.volume39-
dc.citation.number10-
dc.citation.startPage1528-
dc.citation.endPage1533-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusPOLY(METHYL METHACRYLATE)-
dc.subject.keywordPlusCHAMBER DEPTH-
dc.subject.keywordPlusPOSITION-
dc.subject.keywordPlusSILICONE-
dc.subject.keywordPlusCAPSULE-
dc.subject.keywordPlusPOLYMETHYLMETHACRYLATE-
dc.subject.keywordPlusCAPSULORHEXIS-
dc.subject.keywordPlusDECENTRATION-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusERROR-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE