Evaluation of the Influence of Rotor Axial Air Ducts on Condition Monitoring of Induction Motors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Sungho | - |
dc.contributor.author | Hong, Jongman | - |
dc.contributor.author | Lee, Sang Bin | - |
dc.contributor.author | Wiedenbrug, Ernesto J. | - |
dc.contributor.author | Teska, Mike | - |
dc.contributor.author | Kim, Heedong | - |
dc.date.accessioned | 2021-09-05T22:04:42Z | - |
dc.date.available | 2021-09-05T22:04:42Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-09 | - |
dc.identifier.issn | 0093-9994 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/102256 | - |
dc.description.abstract | Rotor axial air ducts are used in large motors for cooling and for reducing weight and material. The rotor axial ducts can produce twice-slip-frequency (2sf(s)) components in the vibration or a current spectrum that can be misinterpreted as induction-motor rotor faults. There is currently no practical solution to the air-duct-induced false positive indications, which is an ongoing problem in the field. However, there are only a few publications that report the issues caused by rotor axial ducts. In this paper, the influence of the rotor air ducts on motor condition monitoring is analyzed and investigated through testing in the field on 6.6-kV motors and in the laboratory. The experimental study shows that the magnitude of the 2sf(s) component due to axial ducts depend on the design, material, construction, and operating conditions of the motor. It is also shown that the 2sf(s) component can even decrease with broken bars, depending on the fault position relative to the ducts, which makes online condition monitoring difficult. Guidelines for reliable motor testing and interpretation of test results are also provided. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | MACHINES | - |
dc.title | Evaluation of the Influence of Rotor Axial Air Ducts on Condition Monitoring of Induction Motors | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Sang Bin | - |
dc.identifier.doi | 10.1109/TIA.2013.2259132 | - |
dc.identifier.wosid | 000324832300012 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, v.49, no.5 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.title | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.volume | 49 | - |
dc.citation.number | 5 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordPlus | MACHINES | - |
dc.subject.keywordAuthor | AC machine | - |
dc.subject.keywordAuthor | axial cooling duct | - |
dc.subject.keywordAuthor | condition monitoring | - |
dc.subject.keywordAuthor | diagnostics | - |
dc.subject.keywordAuthor | electrical fault detection | - |
dc.subject.keywordAuthor | induction motor | - |
dc.subject.keywordAuthor | magnetic asymmetry | - |
dc.subject.keywordAuthor | shaft spider | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.