A simple novel endoscopic successive suture device: a validation study for closure strength and reproducibility

Authors
Song, Y.Choi, H. S.Kim, K.Kim, Y.Kim, B. G.Hong, D.Keum, B.Chun, H. J.
Issue Date
8월-2013
Publisher
GEORG THIEME VERLAG KG
Citation
ENDOSCOPY, v.45, no.8, pp.655 - 660
Indexed
SCIE
SCOPUS
Journal Title
ENDOSCOPY
Volume
45
Number
8
Start Page
655
End Page
660
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/102529
DOI
10.1055/s-0033-1344214
ISSN
0013-726X
Abstract
Background and study aims: Endoscopic surgical technology has been developing rapidly. Although several successful endoscopic closure devices have already been introduced, only a few of them have demonstrated improvements in closure strength and reproducibility over conventional endoscopic clip closures or hand sutures. The objective of this study was to test the feasibility of a novel successive suturing device (SSD) by measuring closure strength and reproducibility. Material and methods: Porcine stomach models were used in this study. Endoclips, full-thickness hand sutures, and the novel SSD sutures were used to close a perforation in the stomach wall, with 10 stomachs being tested for each closure method. Endoclips and SSD sutures were performed using a two-channel endoscope, and the hand sutures were performed from outside of the stomach wall. Air leakage pressure was measured to determine the closure strength and reproducibility of each method. Results: The mean air leakage pressure of the SSD closure was 62.7 +/- 8.2 mmHg. SSD-treated stomachs exhibited significantly greater air leakage pressure than Endoclip-treated stomachs. The standard deviation of bursting pressure in SSD stomachs was found to be significantly smaller than that of hand-sewn stomachs but was not different from that of Endoclip stomachs. Conclusions: The consistent closure strength of SSD stomachs demonstrated the reliability and reproducibility of this new closure method. These promising results in closure strength and reproducibility suggest the feasibility of the proposed device for clinical applications.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Keum, Bo ra photo

Keum, Bo ra
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE