Estimate of the risk of radiation-induced cancers after linear-accelerator-based breast-cancer radiotherapy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Koh, Eui Kwan | - |
dc.contributor.author | Seo, Jungju | - |
dc.contributor.author | Baek, Tae Seong | - |
dc.contributor.author | Chung, Eun Ji | - |
dc.contributor.author | Yoon, Myonggeun | - |
dc.contributor.author | Lee, Hyun-ho | - |
dc.date.accessioned | 2021-09-06T00:08:15Z | - |
dc.date.available | 2021-09-06T00:08:15Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-07 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/102804 | - |
dc.description.abstract | The aim of this study is to assess and compare the excess absolute risks (EARs) of radiation-induced cancers following conformal (3D-CRT), fixed-field intensity-modulated (IMRT) and volumetric modulated arc (RapidArc) radiation therapy in patients with breast cancer. 3D-CRT, IMRT and RapidArc were planned for 10 breast cancer patients. The organ-specific EAR for cancer induction was estimated using the organ equivalent dose (OED) based on computed dose volume histograms (DVHs) and the secondary doses measured at various points from the field edge. The average secondary dose per Gy treatment dose from 3D-CRT, measured 10 to 50 cm from the field edge, ranged from 8.27 to 1.04 mGy. The secondary doses per Gy from IMRT and RapidArc, however, ranged between 5.86 and 0.54 mGy, indicating that IMRT and RapidArc are associated with smaller doses of secondary radiation than 3D-CRT. The organ specific EARs for out-of-field organs, such as the thyroid, liver and colon, were higher with 3D-CRT than with IMRT or RapidArc. In contrast, EARs for in-field organs were much lower with 3D-CRT than with IMRT or RapidArc. The overall estimate of EAR indicated that the radiation-induced cancer risk was 1.8-2.0 times lower with 3D-CRT than with IMRT or RapidArc. Comparisons of EARs during breast irradiation suggested that the predicted risk of secondary cancers was lower with 3D-CRT than with IMRT or RapidArc. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | VOLUMETRIC MODULATED ARC | - |
dc.subject | CONTRALATERAL BREAST | - |
dc.subject | 2ND CANCERS | - |
dc.subject | THERAPY | - |
dc.subject | IRRADIATION | - |
dc.subject | COHORTS | - |
dc.title | Estimate of the risk of radiation-induced cancers after linear-accelerator-based breast-cancer radiotherapy | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Myonggeun | - |
dc.identifier.doi | 10.3938/jkps.63.97 | - |
dc.identifier.scopusid | 2-s2.0-84880431165 | - |
dc.identifier.wosid | 000321973000017 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.63, no.1, pp.97 - 103 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 63 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 97 | - |
dc.citation.endPage | 103 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001819788 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordPlus | VOLUMETRIC MODULATED ARC | - |
dc.subject.keywordPlus | CONTRALATERAL BREAST | - |
dc.subject.keywordPlus | 2ND CANCERS | - |
dc.subject.keywordPlus | THERAPY | - |
dc.subject.keywordPlus | IRRADIATION | - |
dc.subject.keywordPlus | COHORTS | - |
dc.subject.keywordAuthor | Breast radiotherapy | - |
dc.subject.keywordAuthor | Radiation-induced cancer | - |
dc.subject.keywordAuthor | EAR | - |
dc.subject.keywordAuthor | OED | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.