Zinc oxide inverse opal enzymatic biosensor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | You, Xueqiu | - |
dc.contributor.author | Pikul, James H. | - |
dc.contributor.author | King, William P. | - |
dc.contributor.author | Pak, James J. | - |
dc.date.accessioned | 2021-09-06T00:31:09Z | - |
dc.date.available | 2021-09-06T00:31:09Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-06-24 | - |
dc.identifier.issn | 0003-6951 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/102941 | - |
dc.description.abstract | We report ZnO inverse opal- and nanowire (NW)-based enzymatic glucose biosensors with extended linear detection ranges. The ZnO inverse opal sensors have 0.01-18 mM linear detection range, which is 2.5 times greater than that of ZnO NW sensors and 1.5 times greater than that of other reported ZnO sensors. This larger range is because of reduced glucose diffusivity through the inverse opal geometry. The ZnO inverse opal sensors have an average sensitivity of 22.5 mu A/(mM cm(2)), which diminished by 10% after 35 days, are more stable than ZnO NW sensors whose sensitivity decreased by 10% after 7 days. (C) 2013 AIP Publishing LLC. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER INST PHYSICS | - |
dc.subject | GLUCOSE BIOSENSOR | - |
dc.subject | ZNO NANORODS | - |
dc.subject | IMMOBILIZATION | - |
dc.subject | DIFFUSION | - |
dc.subject | GROWTH | - |
dc.title | Zinc oxide inverse opal enzymatic biosensor | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Pak, James J. | - |
dc.identifier.doi | 10.1063/1.4811411 | - |
dc.identifier.scopusid | 2-s2.0-84879874080 | - |
dc.identifier.wosid | 000321145200074 | - |
dc.identifier.bibliographicCitation | APPLIED PHYSICS LETTERS, v.102, no.25 | - |
dc.relation.isPartOf | APPLIED PHYSICS LETTERS | - |
dc.citation.title | APPLIED PHYSICS LETTERS | - |
dc.citation.volume | 102 | - |
dc.citation.number | 25 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | GLUCOSE BIOSENSOR | - |
dc.subject.keywordPlus | ZNO NANORODS | - |
dc.subject.keywordPlus | IMMOBILIZATION | - |
dc.subject.keywordPlus | DIFFUSION | - |
dc.subject.keywordPlus | GROWTH | - |
dc.subject.keywordAuthor | Zinc oxide | - |
dc.subject.keywordAuthor | inverse opal | - |
dc.subject.keywordAuthor | enzyme. biosensor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.