The effect of pulmonary blood flow changes on oxygen-enhanced lung magnetic resonance imaging
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hye-Jeong | - |
dc.contributor.author | Park, Jaeseok | - |
dc.contributor.author | Hur, Jin | - |
dc.contributor.author | Kim, Young Jin | - |
dc.contributor.author | Nam, Ji Eun | - |
dc.contributor.author | Choi, Byoung Wook | - |
dc.contributor.author | Choe, Kyu Ok | - |
dc.date.accessioned | 2021-09-06T00:55:19Z | - |
dc.date.available | 2021-09-06T00:55:19Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2013-06 | - |
dc.identifier.issn | 0740-3194 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103034 | - |
dc.description.abstract | In this study, we investigated the effects of changes in pulmonary blood flow on oxygen-enhanced lung magnetic resonance imaging. Increased pulmonary blood flow was produced by intravenous infusion of sildenafil (0.2 mg/kg) in 10 New Zealand white rabbits. Decreased pulmonary blood flow was produced by single subcutaneous injection of monocrotaline (60 mg/kg). A velocity-encoded cine magnetic resonance imaging for pulmonary blood flow and an oxygen-enhanced lung magnetic resonance imaging were performed at baseline, during sildenafil infusion, and after monocrotaline injection. We compared the baseline data to those obtained during sildenafil infusion and after monocrotaline injection for pulmonary blood flow changes and signal intensity enhancement ratios of oxygen-enhanced lung magnetic resonance imaging. Wilcoxon's signed rank test was used for statistical analysis. There was a significant difference between pulmonary blood flow at baseline (418.6 +/- 108.9 mL/min) and after sildenafil (491.9 +/- 118.0 mL/min; P = 0.005) or between pulmonary blood flow at baseline and after monocrotaline administration (356.3 +/- 85.8 mL/min; P = 0.017). However, there was no significant difference between the signal intensity enhancement ratios at baseline (23.8 +/- 11.4%) and after sildenafil (24.0 +/- 7.9%; P = 0.953) or the signal intensity enhancement ratios at baseline and after monocrotaline administration (22.7 +/- 10.3%; P = 0.374). Changes in pulmonary blood flow had little effect on the signal intensity enhancement ratio of oxygen-enhanced lung magnetic resonance imaging. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | VENTILATION | - |
dc.title | The effect of pulmonary blood flow changes on oxygen-enhanced lung magnetic resonance imaging | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Jaeseok | - |
dc.identifier.doi | 10.1002/mrm.24388 | - |
dc.identifier.scopusid | 2-s2.0-84878114873 | - |
dc.identifier.wosid | 000319074100015 | - |
dc.identifier.bibliographicCitation | MAGNETIC RESONANCE IN MEDICINE, v.69, no.6, pp.1645 - 1649 | - |
dc.relation.isPartOf | MAGNETIC RESONANCE IN MEDICINE | - |
dc.citation.title | MAGNETIC RESONANCE IN MEDICINE | - |
dc.citation.volume | 69 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1645 | - |
dc.citation.endPage | 1649 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | VENTILATION | - |
dc.subject.keywordAuthor | magnetic resonance imaging | - |
dc.subject.keywordAuthor | ventilation | - |
dc.subject.keywordAuthor | oxygen | - |
dc.subject.keywordAuthor | pulmonary function | - |
dc.subject.keywordAuthor | pulmonary perfusion | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.