Effect of the use of a ready-made plastic stent on the peri-implant soft tissue
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Huh, Jung-Bo | - |
dc.contributor.author | Yang, Ki-Bin | - |
dc.contributor.author | Choi, Jeomil | - |
dc.contributor.author | Jeon, Young-Chan | - |
dc.contributor.author | Lee, Jeong-Yeol | - |
dc.contributor.author | Shin, Sang-Wan | - |
dc.date.accessioned | 2021-09-06T01:43:49Z | - |
dc.date.available | 2021-09-06T01:43:49Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2013-05 | - |
dc.identifier.issn | 0001-6357 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103272 | - |
dc.description.abstract | Objective. This study compared the effect of the use of a ready-made plastic stent on the width of peri-implant keratinized mucosa with that of conventional methods and examined the effects of a plastic stent on peri-implant soft tissue. Materials and methods. Five young-adult beagle dogs were used. Forty titanium implants were placed in the mandibular alveolar ridge. Stage 2 surgery was performed 8 weeks after implant installation. Each dog received a full-thickness, apically positioned flap (fAPF) with a lingual crestal incision using a suture material in the control group (n = 20) and a ready-made plastic stent in the test group (n = 20). The keratinized mucosa width after stage 2 surgery was measured in each group. The pocket depth, length of connective-tissue contact and biological width were measured in the tissue samples. A student's t-test was used to test the differences between the groups (95% confidence level). Results. The width of the keratinized mucosa was significantly higher and the distance from the top of the implant platform to the mucogingival junction was significantly longer in the test group than the control group. Histometric observations revealed the pocket depth and biological width to be significantly lower in the test group than the control group. Conclusion. The use of a fAPF with a lingual crestal incision using a ready-made plastic stent can effectively preserve or enhance the width of the keratinized mucosa and might restore a more optimal biological environment at the early soft-tissue healing stage. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | TAYLOR & FRANCIS LTD | - |
dc.subject | OSSEOINTEGRATED TITANIUM FIXTURES | - |
dc.subject | DENTAL IMPLANTS | - |
dc.subject | KERATINIZED MUCOSA | - |
dc.subject | WIDTH | - |
dc.subject | GINGIVA | - |
dc.subject | HEALTH | - |
dc.subject | DIMENSION | - |
dc.title | Effect of the use of a ready-made plastic stent on the peri-implant soft tissue | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jeong-Yeol | - |
dc.contributor.affiliatedAuthor | Shin, Sang-Wan | - |
dc.identifier.doi | 10.3109/00016357.2012.734408 | - |
dc.identifier.scopusid | 2-s2.0-84877313723 | - |
dc.identifier.wosid | 000322832200069 | - |
dc.identifier.bibliographicCitation | ACTA ODONTOLOGICA SCANDINAVICA, v.71, no.3-4, pp.841 - 847 | - |
dc.relation.isPartOf | ACTA ODONTOLOGICA SCANDINAVICA | - |
dc.citation.title | ACTA ODONTOLOGICA SCANDINAVICA | - |
dc.citation.volume | 71 | - |
dc.citation.number | 3-4 | - |
dc.citation.startPage | 841 | - |
dc.citation.endPage | 847 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | OSSEOINTEGRATED TITANIUM FIXTURES | - |
dc.subject.keywordPlus | DENTAL IMPLANTS | - |
dc.subject.keywordPlus | KERATINIZED MUCOSA | - |
dc.subject.keywordPlus | WIDTH | - |
dc.subject.keywordPlus | GINGIVA | - |
dc.subject.keywordPlus | HEALTH | - |
dc.subject.keywordPlus | DIMENSION | - |
dc.subject.keywordAuthor | apically positioned flap | - |
dc.subject.keywordAuthor | biologic width | - |
dc.subject.keywordAuthor | dental implant | - |
dc.subject.keywordAuthor | keratinized mucosa | - |
dc.subject.keywordAuthor | ready-made plastic stent | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.