Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Computed Tomographic Dimensions of the Lacrimal Gland in Healthy Orbits

Authors
Lee, Joon SikLee, HwaKim, Jung WanChang, MinwookPark, MinsooBaek, Sehyun
Issue Date
5월-2013
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
Lacrimal gland dimension; orbital CT; normal Korean orbit
Citation
JOURNAL OF CRANIOFACIAL SURGERY, v.24, no.3, pp.712 - 715
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF CRANIOFACIAL SURGERY
Volume
24
Number
3
Start Page
712
End Page
715
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/103421
DOI
10.1097/SCS.0b013e31827fecc0
ISSN
1049-2275
Abstract
Purpose: The aims of this study were to evaluate the normal range of the dimensions of lacrimal glands in the healthy orbits of Korean subjects and to evaluate their association with clinical findings. Methods: A retrospective survey of patients who had visited the Korea University Medical Center and had undergone orbital computed tomographic scan was performed. One hundred eighty Korean patients (90 men and 90 women) who were older than 20 years and without orbital disease were included. Patients with trauma to the orbits or any known lacrimal gland disease were excluded. The length and width of the lacrimal gland were measured in axial and coronal sections using the largest image. The primary outcome was a descriptive analysis of the distribution of dimensions in normal orbits. We analyzed the results and identified associations with age, sex, and laterality and compared our results with a previous study on normal white lacrimal gland dimensions. Results: The mean lacrimal gland axial length was 14.9 mm in the right orbit and 14.7 mm in left orbit. Coronal lengths averaged 20.9 mm in the right orbit and 20.7 mm in the left orbit. The axial width was 4.1 mm in the right orbit and 4.3 mm in the left orbit. The coronal width averaged 3.6 mm in the right orbit and 3.8 mm in the left orbit. A significant inverse linear relationship was observed in both orbits between gland size and age in all dimensions, with the exception of axial width. Conclusions: This study presents a normal range of Korean lacrimal gland dimensions as measured by computed tomography. This range can aid in differentiating diseased and nondiseased lacrimal glands, especially when used in combination with physical examination. These data may also be useful in clinical trials that involve lacrimal gland size.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Baek, Se Hyun photo

Baek, Se Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE