Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Jeong-Yol | - |
dc.contributor.author | Choi, Sang-Jin | - |
dc.contributor.author | Kim, Min-Soo | - |
dc.contributor.author | Kim, Ha-Young | - |
dc.contributor.author | Kim, Young-Soo | - |
dc.contributor.author | Shin, Sang-Wan | - |
dc.date.accessioned | 2021-09-06T02:14:30Z | - |
dc.date.available | 2021-09-06T02:14:30Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2013-05 | - |
dc.identifier.issn | 2005-7806 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103434 | - |
dc.description.abstract | PURPOSE. The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS. Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope (AXIO (R), Carl Zeiss, Rochester, NY) and software (I-solution (R), IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (alpha=.05). RESULTS. There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 mu m. CONCLUSION. Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN ACAD PROSTHODONTICS | - |
dc.subject | FIXED PARTIAL DENTURES | - |
dc.subject | ALL-CERAMIC CROWNS | - |
dc.subject | FUSED-TO-METAL | - |
dc.subject | MARGINAL FIT | - |
dc.subject | CLINICAL FIT | - |
dc.subject | COPINGS | - |
dc.subject | DESIGN | - |
dc.title | Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jeong-Yol | - |
dc.contributor.affiliatedAuthor | Shin, Sang-Wan | - |
dc.identifier.doi | 10.4047/jap.2013.5.2.118 | - |
dc.identifier.scopusid | 2-s2.0-84883140906 | - |
dc.identifier.wosid | 000324661100007 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ADVANCED PROSTHODONTICS, v.5, no.2, pp.118 - 125 | - |
dc.relation.isPartOf | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.title | JOURNAL OF ADVANCED PROSTHODONTICS | - |
dc.citation.volume | 5 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 118 | - |
dc.citation.endPage | 125 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001771264 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | FIXED PARTIAL DENTURES | - |
dc.subject.keywordPlus | ALL-CERAMIC CROWNS | - |
dc.subject.keywordPlus | FUSED-TO-METAL | - |
dc.subject.keywordPlus | MARGINAL FIT | - |
dc.subject.keywordPlus | CLINICAL FIT | - |
dc.subject.keywordPlus | COPINGS | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordAuthor | Zirconia | - |
dc.subject.keywordAuthor | CAD/CAM | - |
dc.subject.keywordAuthor | Span length | - |
dc.subject.keywordAuthor | Fit | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.