Comparison of femoral tunnel length between transportal and retrograde reaming outside-in techniques in anterior cruciate ligament reconstruction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jae Gyoon | - |
dc.contributor.author | Wang, Joon Ho | - |
dc.contributor.author | Ahn, Jin Hwan | - |
dc.contributor.author | Kim, Hak Jun | - |
dc.contributor.author | Lim, Hong Chul | - |
dc.date.accessioned | 2021-09-06T02:53:03Z | - |
dc.date.available | 2021-09-06T02:53:03Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-04 | - |
dc.identifier.issn | 0942-2056 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103591 | - |
dc.description.abstract | To evaluate the accuracy of intraoperative femoral tunnel length measurement and to compare this between the transportal (TP) and outside-in (OI) techniques for double-bundle (DB) anterior cruciate ligament (ACL) reconstruction. Eighty patients underwent a DB ACL reconstruction using either the TP or the OI technique. The participants were randomized to either a TP group (I, 40 cases) or a OI group (II, 40 cases). The intraoperatively measured femoral tunnel length was recorded, and the postoperative femoral tunnel length was measured using computed tomography with OsiriX(A (R)) imaging software. The mean femoral tunnel lengths measured intraoperatively in Group II (38.9 +/- A 3.0 mm for anteromedial [AM], 39.3 +/- A 3.4 mm for posterolateral [PL]) were significantly longer than those of Group I (34.8 +/- A 2.7 mm for AM, 36.0 +/- A 3.2 mm for PL) (P < 0.001). The mean AM femoral tunnel length measured postoperatively in Group II (33.3 +/- A 3.8 mm) was significantly longer than that in Group I (31.1 +/- A 2.9 mm) (P = 0.006). The mean intraoperatively measured femoral tunnel length was significantly longer than that measured postoperatively in Groups I and II (P < 0.001). After anatomic DB ACL reconstruction, the femoral tunnel length of the OI technique measured intraoperatively (AM/PL) and postoperatively (AM) was longer than those of the TP technique. The femoral tunnel length measured intraoperatively was longer than that measured postoperatively in both TP and OI technique. This study may help surgeons to measure femoral tunnel length accurately in anatomic DB ACL reconstruction with suspensory fixation device. Prospective randomized controlled trial, Level I. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.subject | INTERFERENCE FIT FIXATION | - |
dc.subject | BONE TUNNEL | - |
dc.subject | HAMSTRING TENDONS | - |
dc.subject | GRAFT FIXATION | - |
dc.subject | CROSS-PIN | - |
dc.subject | FOLLOW-UP | - |
dc.subject | ENDOBUTTON | - |
dc.subject | STABILITY | - |
dc.subject | MODEL | - |
dc.subject | SHEEP | - |
dc.title | Comparison of femoral tunnel length between transportal and retrograde reaming outside-in techniques in anterior cruciate ligament reconstruction | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Jae Gyoon | - |
dc.contributor.affiliatedAuthor | Kim, Hak Jun | - |
dc.contributor.affiliatedAuthor | Lim, Hong Chul | - |
dc.identifier.doi | 10.1007/s00167-012-2024-4 | - |
dc.identifier.scopusid | 2-s2.0-84875375505 | - |
dc.identifier.wosid | 000316678300011 | - |
dc.identifier.bibliographicCitation | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v.21, no.4, pp.830 - 838 | - |
dc.relation.isPartOf | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY | - |
dc.citation.title | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY | - |
dc.citation.volume | 21 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 830 | - |
dc.citation.endPage | 838 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalResearchArea | Sport Sciences | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Sport Sciences | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | INTERFERENCE FIT FIXATION | - |
dc.subject.keywordPlus | BONE TUNNEL | - |
dc.subject.keywordPlus | HAMSTRING TENDONS | - |
dc.subject.keywordPlus | GRAFT FIXATION | - |
dc.subject.keywordPlus | CROSS-PIN | - |
dc.subject.keywordPlus | FOLLOW-UP | - |
dc.subject.keywordPlus | ENDOBUTTON | - |
dc.subject.keywordPlus | STABILITY | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | SHEEP | - |
dc.subject.keywordAuthor | Anterior cruciate ligament | - |
dc.subject.keywordAuthor | Transportal | - |
dc.subject.keywordAuthor | Retrograde reaming | - |
dc.subject.keywordAuthor | Outside-in | - |
dc.subject.keywordAuthor | Femoral tunnel length | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.