Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Set-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation

Full metadata record
DC Field Value Language
dc.contributor.authorYang, D. S.-
dc.contributor.authorYoon, W. S.-
dc.contributor.authorChung, S. Y.-
dc.contributor.authorLee, J. A.-
dc.contributor.authorLee, S.-
dc.contributor.authorPark, Y. J.-
dc.contributor.authorKim, C. Y.-
dc.contributor.authorSon, G. S.-
dc.date.accessioned2021-09-06T03:03:15Z-
dc.date.available2021-09-06T03:03:15Z-
dc.date.created2021-06-14-
dc.date.issued2013-04-
dc.identifier.issn0179-7158-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/103620-
dc.description.abstractThe aim of this work was to establish a customized strategy for image-guided radiotherapy during whole breast irradiation. Risk factors associated with extensive errors were assessed. A series of 176 consecutive breasts in 174 patients were retrospectively assessed. Electronic portal images from 914 medial and 807 lateral directions were reviewed. On the basis of the chest wall, the deviations between the simulation and each treatment were measured. The systematic (I ) pound and random error (sigma) of population, and the planning target volume (PTV) margin (2 I pound + 0.7 sigma) were calculated for each direction. Extensive set-up errors were defined as the fraction over the PTV margins in any direction. For extensive set-up errors, chi(2) tests and logistic regression analyses were conducted. The medial and lateral PTV margins for the right-left, superior-inferior, and anterior-posterior axes and the rotation of collimator were 2.6 and 2.4 mm, 4.6 and 4.6 mm, and 3.1 and 3.3 mm and 2.8 and 2.9 A degrees and cut-off values for extensive errors were 3, 5, and 4 mm and 3 A degrees, respectively. In chi(2) tests, tumor in upper outer quadrant (p = 0.012) and chest wall thickness a parts per thousand yenaEuro parts per thousand 2.0 cm (p = 0.003) for medial portals and age group (p = 0.036) for lateral portals were associated with extensive errors. In multivariate tests, the extensive error on the initial fraction had a high probability of extensive set-up errors in both medial (OR = 4.26, p < 0.001) and lateral portals (OR = 3.07, p < 0.001). In terms of the set-up uncertainty during breast irradiation, patients with extensive error in the initial treatment should be closely observed with serial image-guided radiotherapy.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER HEIDELBERG-
dc.subjectRADIATION-THERAPY-
dc.subjectLUMPECTOMY CAVITY-
dc.subjectRANDOMIZED-TRIAL-
dc.subjectIRRADIATION-
dc.subjectERRORS-
dc.subjectMOVEMENT-
dc.subjectEFFICACY-
dc.subjectIMRT-
dc.titleSet-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation-
dc.typeArticle-
dc.contributor.affiliatedAuthorYang, D. S.-
dc.contributor.affiliatedAuthorYoon, W. S.-
dc.contributor.affiliatedAuthorLee, S.-
dc.contributor.affiliatedAuthorKim, C. Y.-
dc.contributor.affiliatedAuthorSon, G. S.-
dc.identifier.doi10.1007/s00066-012-0271-4-
dc.identifier.scopusid2-s2.0-84877269369-
dc.identifier.wosid000316401400005-
dc.identifier.bibliographicCitationSTRAHLENTHERAPIE UND ONKOLOGIE, v.189, no.4, pp.315 - 320-
dc.relation.isPartOfSTRAHLENTHERAPIE UND ONKOLOGIE-
dc.citation.titleSTRAHLENTHERAPIE UND ONKOLOGIE-
dc.citation.volume189-
dc.citation.number4-
dc.citation.startPage315-
dc.citation.endPage320-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOncology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryOncology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusLUMPECTOMY CAVITY-
dc.subject.keywordPlusRANDOMIZED-TRIAL-
dc.subject.keywordPlusIRRADIATION-
dc.subject.keywordPlusERRORS-
dc.subject.keywordPlusMOVEMENT-
dc.subject.keywordPlusEFFICACY-
dc.subject.keywordPlusIMRT-
dc.subject.keywordAuthorBreast cancer-
dc.subject.keywordAuthorSet-up error-
dc.subject.keywordAuthorRisk factor-
dc.subject.keywordAuthorElectronic portal image-
dc.subject.keywordAuthorImage-guided radiotherapy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Son, Gil Soo photo

Son, Gil Soo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE