Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Comparative Reliability and Performance Study of Different Stent Designs in Terms of Mechanical Properties: Foreshortening, Recoil, Radial Force, and Flexibility

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Dong Bin-
dc.contributor.authorChoi, Hyuk-
dc.contributor.authorJoo, Sang Min-
dc.contributor.authorKim, Han Ki-
dc.contributor.authorShin, Jae Hee-
dc.contributor.authorHwang, Min Ho-
dc.contributor.authorChoi, Jaesoon-
dc.contributor.authorKim, Dong-Gon-
dc.contributor.authorLee, Kwang Ho-
dc.contributor.authorLim, Chun Hak-
dc.contributor.authorYoo, Sun Kook-
dc.contributor.authorLee, Heung-Man-
dc.contributor.authorSun, Kyung-
dc.date.accessioned2021-09-06T03:03:36Z-
dc.date.available2021-09-06T03:03:36Z-
dc.date.created2021-06-14-
dc.date.issued2013-04-
dc.identifier.issn0160-564X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/103622-
dc.description.abstractThis study seeks to improve the mechanical performance of stents by conducting reliability performance testing and finite element method (FEM)-based simulations for coronary stents. Three commercially available stent designs and our own new design were tested to measure the factors affecting performance, specifically foreshortening, recoil, radial force, and flexibility. The stents used in the present experiments were 3mm in working diameter and 18mm of working length. The results of the experiments indicate that the foreshortening of stents A, B, C, and our new design, D, was equivalent to 2.25, 0.67, 0.46, and 0.41%, respectively. The recoil of stents A, B, C, and D was 6.00, 4.35, 3.50, and 4.36%, respectively. Parallel plate radial force measurements were A, 3.72 +/- 0.28N; B, 3.81 +/- 0.32N; C, 4.35 +/- 0.18N; and D, 4.02 +/- 0.24N. Radial forces determined by applying uniform pressure in the circumferential direction were A, 28.749 +/- 0.81N; B, 32.231 +/- 1.80N; C, 34.522 +/- 3.06N; and D, 42.183 +/- 2.84N. The maximum force of crimped stent at 2.2-mm deflection was 1.01 +/- 0.08N, 0.82 +/- 0.08N, 0.92 +/- 0.12N, and 0.68 +/- 0.07N for each of stents A, B, C and D. The results of this study enabled us to identify several factors to enhance the performance of stents. In comparing these stents, we found that our design, stent D, which was designed by a collaborative team from seven universities, performed better than the commercial stents across all parameter of foreshortening, recoil, radial force, and flexibility.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-BLACKWELL-
dc.subjectBARE-METAL STENTS-
dc.subjectDRUG-ELUTING STENTS-
dc.subjectCORONARY STENT-
dc.subjectFOLLOW-UP-
dc.subjectSAFETY-
dc.subjectRESTENOSIS-
dc.subjectTHROMBOSIS-
dc.subjectEFFICACY-
dc.subjectSYSTEM-
dc.subjectOUTCOMES-
dc.titleA Comparative Reliability and Performance Study of Different Stent Designs in Terms of Mechanical Properties: Foreshortening, Recoil, Radial Force, and Flexibility-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hyuk-
dc.contributor.affiliatedAuthorHwang, Min Ho-
dc.contributor.affiliatedAuthorLim, Chun Hak-
dc.contributor.affiliatedAuthorLee, Heung-Man-
dc.contributor.affiliatedAuthorSun, Kyung-
dc.identifier.doi10.1111/aor.12001-
dc.identifier.scopusid2-s2.0-84875963938-
dc.identifier.wosid000317332600005-
dc.identifier.bibliographicCitationARTIFICIAL ORGANS, v.37, no.4, pp.368 - 379-
dc.relation.isPartOfARTIFICIAL ORGANS-
dc.citation.titleARTIFICIAL ORGANS-
dc.citation.volume37-
dc.citation.number4-
dc.citation.startPage368-
dc.citation.endPage379-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.subject.keywordPlusBARE-METAL STENTS-
dc.subject.keywordPlusDRUG-ELUTING STENTS-
dc.subject.keywordPlusCORONARY STENT-
dc.subject.keywordPlusFOLLOW-UP-
dc.subject.keywordPlusSAFETY-
dc.subject.keywordPlusRESTENOSIS-
dc.subject.keywordPlusTHROMBOSIS-
dc.subject.keywordPlusEFFICACY-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusOUTCOMES-
dc.subject.keywordAuthorCoronary stent-
dc.subject.keywordAuthorReliability performance testing-
dc.subject.keywordAuthorFlexibility-
dc.subject.keywordAuthorRecoil-
dc.subject.keywordAuthorRadial force-
dc.subject.keywordAuthorUniformity-
dc.subject.keywordAuthorForeshortening-
dc.subject.keywordAuthorFinite element method-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hyuk photo

Choi, Hyuk
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE