Uniformity and stability of the CMS RPC detector at the LHC
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Costantini, S. | - |
dc.contributor.author | Beernaert, K. | - |
dc.contributor.author | Cimmino, A. | - |
dc.contributor.author | Garcia, G. | - |
dc.contributor.author | Lellouch, J. | - |
dc.contributor.author | Marinov, A. | - |
dc.contributor.author | Ocampo, A. | - |
dc.contributor.author | Strobbe, N. | - |
dc.contributor.author | Thyssen, F. | - |
dc.contributor.author | Tytgat, M. | - |
dc.contributor.author | Verwilligen, P. | - |
dc.contributor.author | Yazgan, E. | - |
dc.contributor.author | Zaganidis, N. | - |
dc.contributor.author | Dimitrov, A. | - |
dc.contributor.author | Hadjiiska, R. | - |
dc.contributor.author | Litov, L. | - |
dc.contributor.author | Pavlov, B. | - |
dc.contributor.author | Petkov, P. | - |
dc.contributor.author | Aleksandrov, A. | - |
dc.contributor.author | Genchev, V. | - |
dc.contributor.author | Iaydjiev, P. | - |
dc.contributor.author | Rodozov, M. | - |
dc.contributor.author | Shopova, M. | - |
dc.contributor.author | Sultanov, G. | - |
dc.contributor.author | Ban, Y. | - |
dc.contributor.author | Cai, J. | - |
dc.contributor.author | Ge, Y. | - |
dc.contributor.author | Li, Q. | - |
dc.contributor.author | Qian, S. | - |
dc.contributor.author | Xue, Z. | - |
dc.contributor.author | Avila, C. | - |
dc.contributor.author | Chaparro, L. F. | - |
dc.contributor.author | Gomez, J. P. | - |
dc.contributor.author | Moreno, B. Gomez | - |
dc.contributor.author | Oliveros, A. F. Osorio | - |
dc.contributor.author | Sanabria, J. C. | - |
dc.contributor.author | Assran, Y. | - |
dc.contributor.author | Sharma, A. | - |
dc.contributor.author | Abbrescia, M. | - |
dc.contributor.author | Calabria, C. | - |
dc.contributor.author | Colaleo, A. | - |
dc.contributor.author | Loddo, F. | - |
dc.contributor.author | Maggi, M. | - |
dc.contributor.author | Pugliese, G. | - |
dc.contributor.author | Benussi, L. | - |
dc.contributor.author | Bianco, S. | - |
dc.contributor.author | Colafranceschi, S. | - |
dc.contributor.author | Piccolo, D. | - |
dc.contributor.author | Buontempo, S. | - |
dc.contributor.author | Carrillo, C. | - |
dc.contributor.author | Iorio, O. | - |
dc.contributor.author | Paolucci, P. | - |
dc.contributor.author | Berzano, U. | - |
dc.contributor.author | Gabusi, M. | - |
dc.contributor.author | Vitulo, P. | - |
dc.contributor.author | Kang, M. | - |
dc.contributor.author | Lee, K. S. | - |
dc.contributor.author | Park, S. K. | - |
dc.contributor.author | Shin, S. | - |
dc.contributor.author | Choi, Y. | - |
dc.contributor.author | Goh, J. | - |
dc.contributor.author | Kim, M. S. | - |
dc.contributor.author | Seo, H. | - |
dc.contributor.author | Shoaib, M. | - |
dc.date.accessioned | 2021-09-06T03:50:07Z | - |
dc.date.available | 2021-09-06T03:50:07Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-03 | - |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103815 | - |
dc.description.abstract | The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover, an increased detector stability has been obtained by automatically taking into account temperature and atmospheric pressure variations in the CMS cavern. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | RESISTIVE PLATE CHAMBERS | - |
dc.title | Uniformity and stability of the CMS RPC detector at the LHC | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, S. K. | - |
dc.identifier.doi | 10.1088/1748-0221/8/03/P03017 | - |
dc.identifier.scopusid | 2-s2.0-84877731720 | - |
dc.identifier.wosid | 000316990700042 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INSTRUMENTATION, v.8 | - |
dc.relation.isPartOf | JOURNAL OF INSTRUMENTATION | - |
dc.citation.title | JOURNAL OF INSTRUMENTATION | - |
dc.citation.volume | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | RESISTIVE PLATE CHAMBERS | - |
dc.subject.keywordAuthor | Performance of High Energy Physics Detectors | - |
dc.subject.keywordAuthor | Resistive-plate chambers | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.