Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Use of Corneal Power-Specific Constants to Improve the Accuracy of the SRK/T Formula

Full metadata record
DC Field Value Language
dc.contributor.authorEom, Youngsub-
dc.contributor.authorKang, Su-Yeon-
dc.contributor.authorSong, Jong-Suk-
dc.contributor.authorKim, Hyo Myung-
dc.date.accessioned2021-09-06T03:54:42Z-
dc.date.available2021-09-06T03:54:42Z-
dc.date.created2021-06-14-
dc.date.issued2013-03-
dc.identifier.issn0161-6420-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/103840-
dc.description.abstractPurpose: To evaluate the effect of average corneal power (K) and axial length (AL) in a data-adjusted A-constant for improving the refractive outcome in the Sanders-Retzlaff-Kraff (SRK)/T formula. Design: Retrospective, consecutive, case series. Participants: A total of 637 patients (637 eyes) who underwent uncomplicated phacoemulsification with implantation of the Acrysof IQ (IQ; Alcon, Fort Worth, TX; 314 eyes) or Akreos AO (AO; Bausch & Lomb, Rochester, NY; 323 eyes) intraocular lens (IOL) by a single surgeon. Methods: The correlation among the K, AL, and predicted refractive error in the SRK/T formula was analyzed. Patients were divided into 2 subgroups, the first to calculate the different data-adjusted A-constants based on the K and the second to compare the median absolute error (MedAE) based on different A-constants with the traditional A-constant in the SRK/T formula. Main Outcome Measures: The data-adjusted A-constant and the MedAE (diopters [D]). Results: The data-adjusted A-constant showed a decreasing trend as K increased. The data-adjusted A-constant was 119.04 in the IQ group and 118.27 in the AO group. The calculated A-constant was 119.33 in the IQ group and 118.57 in the AO group when the cornea was flatter than 43.0 D and 43.2 D, respectively. The A-constant was 118.71 in the IQ group and 117.96 in the AO group when the cornea was steeper than or equal to 44.7 D and 45.0 D, respectively. The MedAE decreased from 0.29 D to 0.23 D in the IQ group (P = 0.001) and from 0.44 D to 0.38 D in the AO group (P < 0.001) when different A-constants were used. The MedAE further decreased from 0.36 D to 0.24 D in the IQ group (P = 0.005) and from 0.58 D to 0.37 D in the AO group (P < 0.001) when subjects with K 1.00 D or more above or 1.00 D below the most accurate K in each group were compared. Conclusions: For a steep cornea, the calculated A-constant was smaller than that of the entire K, but for a flat cornea, a larger A-constant was calculated. Using different A-constants based on the K improved the refraction outcomes relying on the SRK/T formula. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2013;120:477-481 (C) 2013 by the American Academy of Ophthalmology.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectINTRAOCULAR-LENS POWER-
dc.subjectANTERIOR-CHAMBER DEPTH-
dc.subjectREFRACTIVE OUTCOMES-
dc.subjectCATARACT-SURGERY-
dc.subject2ND EYE-
dc.titleUse of Corneal Power-Specific Constants to Improve the Accuracy of the SRK/T Formula-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.contributor.affiliatedAuthorSong, Jong-Suk-
dc.contributor.affiliatedAuthorKim, Hyo Myung-
dc.identifier.doi10.1016/j.ophtha.2012.09.008-
dc.identifier.scopusid2-s2.0-84875216376-
dc.identifier.wosid000315738200009-
dc.identifier.bibliographicCitationOPHTHALMOLOGY, v.120, no.3, pp.477 - 481-
dc.relation.isPartOfOPHTHALMOLOGY-
dc.citation.titleOPHTHALMOLOGY-
dc.citation.volume120-
dc.citation.number3-
dc.citation.startPage477-
dc.citation.endPage481-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusINTRAOCULAR-LENS POWER-
dc.subject.keywordPlusANTERIOR-CHAMBER DEPTH-
dc.subject.keywordPlusREFRACTIVE OUTCOMES-
dc.subject.keywordPlusCATARACT-SURGERY-
dc.subject.keywordPlus2ND EYE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE