Label-free, needle-type biosensor for continuous glucose monitoring based on competitive binding
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Paek, Sung-Ho | - |
dc.contributor.author | Cho, Il-Hoon | - |
dc.contributor.author | Kim, Dong-Hyung | - |
dc.contributor.author | Jeon, Jin-Woo | - |
dc.contributor.author | Lim, Guei-Sam | - |
dc.contributor.author | Paek, Se-Hwan | - |
dc.date.accessioned | 2021-09-06T04:24:44Z | - |
dc.date.available | 2021-09-06T04:24:44Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2013-02-15 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/103957 | - |
dc.description.abstract | With the goal of developing a method for the continuous monitoring of blood glucose, an implantable sensor was developed by placing an optical fiber probe within the internal hollow space of a syringe needle. A glucose binder, concanavalin A (Con A), was immobilized on the probe tip and a protein (e.g., bovine serum albumin) chemically coupled with a sugar ligand (e.g., mannose) was loaded as a solution inside of the needle, which were then closed using a semi-permeable membrane. Upon immersion in the glucose sample, small molecules were able to freely pass through the membrane and compete with the ligand conjugate for Con A binding. This changed the molecular layer thickness on the probe surfaces depending on the glucose concentration, which shifted the wavelength of the guided light along the fiber. Such interference in the wavelength pattern was measured using a commercial sensor system, Octet, without employing a label. Using this analytical approach, two major steps controlling the performance of glucose detection were overcome: permeation of glucose (optimum with 50 nm-porous polycarbonate membrane under the experimental conditioned used) and molecular diffusion of the ligand conjugate within the sensor compartment (19 gauge-needle, offering minimal demensions for the probe). Under optimal conditions, the sensor was able to monitor glucose fluctuations, even in serum medium, with a response time of less than 15 min in a range 10-500 mg/dL. This, however, could be further shortened down to about 5 min in principle by miniaturizing the sensor dimensions. (C) 2012 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER ADVANCED TECHNOLOGY | - |
dc.subject | CONCANAVALIN-A | - |
dc.subject | OVALBUMIN | - |
dc.subject | SENSOR | - |
dc.title | Label-free, needle-type biosensor for continuous glucose monitoring based on competitive binding | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Paek, Se-Hwan | - |
dc.identifier.doi | 10.1016/j.bios.2012.05.038 | - |
dc.identifier.scopusid | 2-s2.0-84868664814 | - |
dc.identifier.wosid | 000312825800007 | - |
dc.identifier.bibliographicCitation | BIOSENSORS & BIOELECTRONICS, v.40, no.1, pp.38 - 44 | - |
dc.relation.isPartOf | BIOSENSORS & BIOELECTRONICS | - |
dc.citation.title | BIOSENSORS & BIOELECTRONICS | - |
dc.citation.volume | 40 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 38 | - |
dc.citation.endPage | 44 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biophysics | - |
dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Biophysics | - |
dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.subject.keywordPlus | CONCANAVALIN-A | - |
dc.subject.keywordPlus | OVALBUMIN | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordAuthor | Continuous glucose monitoring | - |
dc.subject.keywordAuthor | Concanavalin A as glucose binder | - |
dc.subject.keywordAuthor | Needle-type implantable sensor | - |
dc.subject.keywordAuthor | Rate-limiting factors | - |
dc.subject.keywordAuthor | Label-free signal detection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.