Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Use of the Posterior Lesser Trochanter Line to Estimate Femoral Neck Version

Full metadata record
DC Field Value Language
dc.contributor.authorShon, Won Yong-
dc.contributor.authorYun, Ho Hyun-
dc.contributor.authorYang, Jae-Hyuk-
dc.contributor.authorSong, Seung Yeop-
dc.contributor.authorPark, Sung Bum-
dc.contributor.authorLee, Jee Wun-
dc.date.accessioned2021-09-06T04:47:50Z-
dc.date.available2021-09-06T04:47:50Z-
dc.date.created2021-06-14-
dc.date.issued2013-02-
dc.identifier.issn0883-5403-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/104089-
dc.description.abstractWe hypothesized that the lesser trochanter could be a useful guide for estimating femoral component version during total hip arthroplasty. We conducted a study of 88 patients to evaluate the relationship between the posterior lesser trochanter line (PLTL) and the femoral neck axis (FNA) using computed tomographic scans. The mean angle between the PLTL and the FNA was 17.4 degrees +/- 7.1 degrees (range, -1.6 degrees to 36.5 degrees). The PLTL angle correlated (r(2) = 0.67-0.72) with the FNA angle. Intraclass correlation coefficient values showed a high level of intraobserver and interobserver agreement in the angles between the PLTL and the FNA. We found a constant relationship between the lesser trochanter and the FNA, and femoral neck version can be estimated, using the PLTL, with reasonable reliability.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS-
dc.subjectCOMPUTED-TOMOGRAPHY-
dc.subjectHIP-ARTHROPLASTY-
dc.subjectANTEVERSION-
dc.subjectDISLOCATION-
dc.subjectRANGE-
dc.subjectOSTEOARTHRITIS-
dc.subjectCOMPONENTS-
dc.subjectDYSPLASIA-
dc.subjectPOSITION-
dc.subjectMOTION-
dc.titleThe Use of the Posterior Lesser Trochanter Line to Estimate Femoral Neck Version-
dc.typeArticle-
dc.contributor.affiliatedAuthorShon, Won Yong-
dc.identifier.doi10.1016/j.arth.2012.03.001-
dc.identifier.scopusid2-s2.0-84872680330-
dc.identifier.wosid000314440600026-
dc.identifier.bibliographicCitationJOURNAL OF ARTHROPLASTY, v.28, no.2, pp.352 - 358-
dc.relation.isPartOfJOURNAL OF ARTHROPLASTY-
dc.citation.titleJOURNAL OF ARTHROPLASTY-
dc.citation.volume28-
dc.citation.number2-
dc.citation.startPage352-
dc.citation.endPage358-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusHIP-ARTHROPLASTY-
dc.subject.keywordPlusANTEVERSION-
dc.subject.keywordPlusDISLOCATION-
dc.subject.keywordPlusRANGE-
dc.subject.keywordPlusOSTEOARTHRITIS-
dc.subject.keywordPlusCOMPONENTS-
dc.subject.keywordPlusDYSPLASIA-
dc.subject.keywordPlusPOSITION-
dc.subject.keywordPlusMOTION-
dc.subject.keywordAuthorhip-
dc.subject.keywordAuthortotal hip arthroplasty-
dc.subject.keywordAuthorposterior lesser trochanter line-
dc.subject.keywordAuthorfemoral neck axis-
dc.subject.keywordAuthorfemoral version-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE