dc.description.abstract | The objective of this study is to evaluate the predictive accuracy of lighting energy consumption carried out by the EnergyPlus program and by the integrated simulation method (ISM), using the Daysim program. EnergyPlus calculates the interior illuminance based on the split-flux and radiosity method, and overestimates the interior illuminance, and we can see large differences in the EnergyPlus interior illuminance results. MBE by the split-flux method was found to range between 81.5% and 463.4%, and the largest MBE occurred at the deepest point. The Daysim program calculates the interior illuminance based on the ray-tracing method, and the largest MBE is -18.9%, at the middle point of the room. Lighting energy consumption differences are caused by the interior illuminance calculation algorithms in the simulation programs. As a result, the lighting energy consumption derived by the EnergyPlus program without ISM is approximately 34.6% smaller, than that of real consumption. The ISM was improved in the prediction accuracy of lighting energy consumption by 24.6% in absolute value. The results of the lighting energy consumption with ISM are relatively more accurate than the EnergyPlus results without ISM, because the modified lighting schedule is similar to the actual situation. (c) 2012 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject | ALL-SKY CONDITIONS | - |
dc.subject | LUMINOUS EFFICACY | - |
dc.subject | DIFFUSE-RADIATION | - |
dc.subject | IRRADIANCE DATA | - |
dc.subject | MODELS | - |
dc.subject | ISRAEL | - |
dc.title | An empirical validation of lighting energy consumption using the integrated simulation method | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Kang Soo | - |
dc.identifier.doi | 10.1016/j.enbuild.2012.10.028 | - |
dc.identifier.scopusid | 2-s2.0-84871738137 | - |
dc.identifier.wosid | 000314735500017 | - |
dc.identifier.bibliographicCitation | ENERGY AND BUILDINGS, v.57, pp.144 - 154 | - |
dc.relation.isPartOf | ENERGY AND BUILDINGS | - |
dc.citation.title | ENERGY AND BUILDINGS | - |
dc.citation.volume | 57 | - |
dc.citation.startPage | 144 | - |
dc.citation.endPage | 154 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordPlus | ALL-SKY CONDITIONS | - |
dc.subject.keywordPlus | LUMINOUS EFFICACY | - |
dc.subject.keywordPlus | DIFFUSE-RADIATION | - |
dc.subject.keywordPlus | IRRADIANCE DATA | - |
dc.subject.keywordPlus | MODELS | - |
dc.subject.keywordPlus | ISRAEL | - |
dc.subject.keywordAuthor | EnergyPlus | - |
dc.subject.keywordAuthor | Daysim | - |
dc.subject.keywordAuthor | Lighting energy | - |
dc.subject.keywordAuthor | Integrated simulation method | - |
dc.subject.keywordAuthor | Illuminance measurement | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.