도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이희정 | - |
dc.contributor.author | 김재홍 | - |
dc.contributor.author | 김웅철 | - |
dc.contributor.author | 김지환 | - |
dc.contributor.author | 김혜영 | - |
dc.date.accessioned | 2021-09-06T07:34:22Z | - |
dc.date.available | 2021-09-06T07:34:22Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1229-3954 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/105052 | - |
dc.description.abstract | Purpose: The aim of this study was to compare with color reproducibility of the coating method and dipping method using a colour liquid. Methods: Two groups of square-shaped specimens (10 10 in diameter, 1.5 thickness) were prepared for analysis(n=15/group). The CM(Coating Method) group was fabricated as full zirconia specimens with the coating coloring method and Group DM(Dipping Method) was prepared as specimens of 0.7 mm-thick zirconia plate using the dipping coloring method and veneered with 0.8mm-thick porcelain. Color parameters were measured with ShadeEye NCC spectrophotometer and color differences were calculated using the equation E* = {(L*)2+( a*)2+( b*)2}1/2. Non-parametric statistical methods, the Mann-Whitney test, and the Kruskal-Wallis test were used to analyze the data. Type one error rate was set at 0.05. Results: Color difference values larger than 7 were observed between specimens with the coating method and the dipping method, which were detectable difference in a clinical setting. Conclusion: Cautious application of the coating coloring method in a clinical setting and further researches to standardize the coating method are needed. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한치과기공학회 | - |
dc.title | 도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구 | - |
dc.title.alternative | Comparative study of color reproducibility of zirconia using a dipping method and coating method | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김웅철 | - |
dc.contributor.affiliatedAuthor | 김지환 | - |
dc.contributor.affiliatedAuthor | 김혜영 | - |
dc.identifier.bibliographicCitation | 대한치과기공학회지, v.35, no.3, pp.185 - 192 | - |
dc.relation.isPartOf | 대한치과기공학회지 | - |
dc.citation.title | 대한치과기공학회지 | - |
dc.citation.volume | 35 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 185 | - |
dc.citation.endPage | 192 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001804213 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | colour liquid | - |
dc.subject.keywordAuthor | veneer | - |
dc.subject.keywordAuthor | all-ceramic crown | - |
dc.subject.keywordAuthor | color difference | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.