Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A comparison between central blood pressure values obtained by the Gaon system and the SphygmoCor system

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Jun Hyuk-
dc.contributor.authorLee, Dae In-
dc.contributor.authorKim, Sua-
dc.contributor.authorKim, Sun Won-
dc.contributor.authorIm, Sung Il-
dc.contributor.authorNa, Jin Oh-
dc.contributor.authorChoi, Cheol Ung-
dc.contributor.authorLim, Hong Euy-
dc.contributor.authorKim, Jin Won-
dc.contributor.authorKim, Eung Ju-
dc.contributor.authorHan, Seung Woo-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorSeo, Hong Seog-
dc.contributor.authorOh, Dong Joo-
dc.contributor.authorPark, Chang Gyu-
dc.date.accessioned2021-09-06T08:17:13Z-
dc.date.available2021-09-06T08:17:13Z-
dc.date.created2021-06-19-
dc.date.issued2012-03-
dc.identifier.issn0916-9636-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/105326-
dc.description.abstractCentral pulse pressure is correlated with carotid atherosclerosis and the incidence of cardiovascular events more significantly than brachial pulse pressure. Augmentation index (Aix) has been shown to be an independent predictor of cardiovascular morbidity and mortality. Pulse wave analysis using the Gaon system allows for the estimation of central blood pressure (CBP), corrected augmentation index (Aix@HR75), ejection duration (ED) and subendocardial viability ratio (SEVR), and is widely used in clinical research in Korea. However, the accuracy of this system is controversial. From February 2008 to March 2011, 99 patients were recruited for this study. Measurements were taken both by the Gaon system and the SphygmoCor system on the same day for all study participants. The estimated values of CBP, Aix@HR75, ED and SEVR for the two systems were compared using paired t-tests, simple correlation analyses and Bland-Altman plots. Systolic blood pressure (SBP) estimated by the two systems was significantly (P<0.001) correlated; the coefficient was 0.982. The two s.d. of the difference in SBP between these systems was quite small-<7mmHg. Aix@HR75, ED and SEVR as estimated by the two systems were also significantly correlated, although they, especially SEVR, showed much weaker correlations than were observed in SBP: coefficients for Aix@HR75, ED and SEVR were 0.727, 0.648 and 0.230, respectively. We assessed the CBP of Korean patients estimated by the two systems and observed that the correlations of Aix, ED and SEVR were weaker than that of CBP. Such variations may be due to the difference in measuring methods between the devices. As even a slight change in pulse waveforms may result in a large difference in estimations, parameters, including Aix@HR75, ED and SEVR, should be carefully interpreted by experienced clinicians. Hypertension Research (2012) 35, 329-333; doi:10.1038/hr.2011.192; published online 8 December 2011-
dc.languageEnglish-
dc.language.isoen-
dc.publisherNATURE PUBLISHING GROUP-
dc.subjectPULSE-WAVE ANALYSIS-
dc.subjectAPPLANATION TONOMETRY-
dc.subjectENDOTHELIAL FUNCTION-
dc.subjectAUGMENTATION INDEX-
dc.subjectRENAL-FAILURE-
dc.subjectREPRODUCIBILITY-
dc.subjectREFLECTIONS-
dc.subjectVELOCITY-
dc.subjectDISEASE-
dc.subjectEVENTS-
dc.titleA comparison between central blood pressure values obtained by the Gaon system and the SphygmoCor system-
dc.typeArticle-
dc.contributor.affiliatedAuthorNa, Jin Oh-
dc.contributor.affiliatedAuthorChoi, Cheol Ung-
dc.contributor.affiliatedAuthorLim, Hong Euy-
dc.contributor.affiliatedAuthorKim, Jin Won-
dc.contributor.affiliatedAuthorKim, Eung Ju-
dc.contributor.affiliatedAuthorHan, Seung Woo-
dc.contributor.affiliatedAuthorRha, Seung-Woon-
dc.contributor.affiliatedAuthorSeo, Hong Seog-
dc.contributor.affiliatedAuthorOh, Dong Joo-
dc.contributor.affiliatedAuthorPark, Chang Gyu-
dc.identifier.doi10.1038/hr.2011.192-
dc.identifier.wosid000301188600015-
dc.identifier.bibliographicCitationHYPERTENSION RESEARCH, v.35, no.3, pp.329 - 333-
dc.relation.isPartOfHYPERTENSION RESEARCH-
dc.citation.titleHYPERTENSION RESEARCH-
dc.citation.volume35-
dc.citation.number3-
dc.citation.startPage329-
dc.citation.endPage333-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.subject.keywordPlusPULSE-WAVE ANALYSIS-
dc.subject.keywordPlusAPPLANATION TONOMETRY-
dc.subject.keywordPlusENDOTHELIAL FUNCTION-
dc.subject.keywordPlusAUGMENTATION INDEX-
dc.subject.keywordPlusRENAL-FAILURE-
dc.subject.keywordPlusREPRODUCIBILITY-
dc.subject.keywordPlusREFLECTIONS-
dc.subject.keywordPlusVELOCITY-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordPlusEVENTS-
dc.subject.keywordAuthoraugmentation index-
dc.subject.keywordAuthorcentral blood pressure-
dc.subject.keywordAuthorpulse wave analysis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Na, Jin Oh photo

Na, Jin Oh
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE