Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Moon Seok | - |
dc.contributor.author | Lee, Kyoung Min | - |
dc.contributor.author | Lee, Boram | - |
dc.contributor.author | Min, Eunki | - |
dc.contributor.author | Kim, Youhyun | - |
dc.contributor.author | Jeon, Sungchae | - |
dc.contributor.author | Huh, Young | - |
dc.contributor.author | Lee, Kisung | - |
dc.date.accessioned | 2021-09-06T08:22:39Z | - |
dc.date.available | 2021-09-06T08:22:39Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2012-03 | - |
dc.identifier.issn | 0144-8420 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/105356 | - |
dc.description.abstract | The O-arm system has recently been introduced and has the capability of combined two-dimensional (2-D) fluoroscopy imaging and three-dimensional computed tomography imaging. In this study, an orthopaedic surgical procedure using C-arm and O-arm systems in their 2-D fluoroscopy modes was simulated and the radiation doses to susceptible organs to which operators can be exposed were investigated. The experiments were performed in four configurations of the location of the X-ray source and detector. Shielding effects on the thyroid surface and the direct exposure delivered to the surgeons hands were also compared. The results obtained show that the O-arm delivered higher doses to the sensitive organs of the operator in all configurations. The thyroid shield cut-off 89 of the dose in the posteroanterior configuration of both imaging systems. Thus, the operators need to pay more attention to managing radiation exposure, especially when using the O-arm system. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | OXFORD UNIV PRESS | - |
dc.subject | EYE PROTECTION | - |
dc.subject | PATIENT | - |
dc.title | Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Kisung | - |
dc.identifier.doi | 10.1093/rpd/ncr149 | - |
dc.identifier.scopusid | 2-s2.0-84863230237 | - |
dc.identifier.wosid | 000300730000007 | - |
dc.identifier.bibliographicCitation | RADIATION PROTECTION DOSIMETRY, v.148, no.4, pp.431 - 438 | - |
dc.relation.isPartOf | RADIATION PROTECTION DOSIMETRY | - |
dc.citation.title | RADIATION PROTECTION DOSIMETRY | - |
dc.citation.volume | 148 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 431 | - |
dc.citation.endPage | 438 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | EYE PROTECTION | - |
dc.subject.keywordPlus | PATIENT | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.