간극이 있는 복합 덕트에서 국부 누셀트수와 온도분포 측정The Measurement of Local Nusselt Number and Temperature Field in the Compound Duct with Gap
- Other Titles
- The Measurement of Local Nusselt Number and Temperature Field in the Compound Duct with Gap
- Authors
- 변재기; 최영돈; 곽동걸; 신종근
- Issue Date
- 2013
- Publisher
- 한국기계기술학회
- Keywords
- Nusselt number(누셀트수); Gap(간극); Heat transfer(열전달); Pulsating flow(맥동유동); Turbulent flow mixing(난류 유동혼합)
- Citation
- 한국기계기술학회지, v.15, no.1, pp.83 - 88
- Indexed
- KCI
OTHER
- Journal Title
- 한국기계기술학회지
- Volume
- 15
- Number
- 1
- Start Page
- 83
- End Page
- 88
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/105545
- DOI
- 10.17958/ksmt.15.1.201302.83
- ISSN
- 1229-604X
- Abstract
- Local Nusselt number and temperature field distribution within the compound duct with gap have been measured. Measurement of air and wall temperature span a range of gap width from 2mm to 6mm. Also, the Reynolds number is variated from 20,000 to 40,0000. In order to observe the correlations between gap width and turbulent heat transfer, the present measurement has tried to verify the enhancement effect of heat transfer when a gap exists within the compound channel. From this measurement, we could see that the pulsating flow has generated a strong turbulent flow mixing within the compound channel. And the turbulent flow mixing in the pulsating flow plays an effective role of enhancing the Nusselt number by making the fluid temperature uniformly within the compound channel.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Mechanical Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.