Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The use of T-LCP (locking compression plate) for the treatment of the lateral malleolar fractures

Full metadata record
DC Field Value Language
dc.contributor.authorKim, H.J.-
dc.contributor.authorOh, J.-K.-
dc.contributor.authorHwang, J.-H.-
dc.contributor.authorPark, Y.H.-
dc.date.accessioned2021-09-06T09:39:27Z-
dc.date.available2021-09-06T09:39:27Z-
dc.date.created2021-06-17-
dc.date.issued2013-
dc.identifier.issn1633-8065-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/105851-
dc.description.abstractBackground: The authors evaluated results and hardware-related complications after the fixation of Danis-Weber (D-W) types A and B lateral malleolus fractures using a 3.5-mm T-shaped locking compression plate (T-LCP) for distal radius. Methods: Twenty-six patients with Danis-Weber type A or B lateral malleolar fractures treated between January 2001 and February 2008 were included in this study. Mean age of the patients was 52.6 (28-77) years. All patients were treated using a 3.5-mm T-shaped locking plate for distal radius fractures. The distal fragment was fixed with at least 2 locking screws more. Ankle motion was allowed early after surgery. The authors evaluated serial radiographs, range of motion, skin irritation, and AOFAS scores at final follow-ups. Results: All fractures united during follow-up. Eight cases were of D-W type A, and 18 were of D-W type B. A mean number of three screws were placed at the distal fragment (2-4). There were 6 cases (23.1%) of implant irritation over the operative site, but no other complications were encountered. At final follow-ups, the AOFAS score of affected ankles was 97.1 ± 4.4. Conclusion: T-LCP use for type A or B lateral malleolar fractures resulted in low hardware-related complications and produced good results at follow-up. © 2012 Springer-Verlag.-
dc.languageEnglish-
dc.language.isoen-
dc.subjectadult-
dc.subjectaged-
dc.subjectAmerican Orthopaedic Foot and Ankle Society score-
dc.subjectankle-
dc.subjectarticle-
dc.subjectclinical article-
dc.subjectcompression plate-
dc.subjectdisease classification-
dc.subjectfemale-
dc.subjectfollow up-
dc.subjectfoot radiography-
dc.subjectfracture fixation-
dc.subjectfracture healing-
dc.subjecthuman-
dc.subjectjoint mobility-
dc.subjectlocking screw-
dc.subjectmale-
dc.subjectmalleolus fracture-
dc.subjectoutcome assessment-
dc.subjectpriority journal-
dc.subjectradius fracture-
dc.subjectrange of motion-
dc.subjectretrospective study-
dc.subjectscoring system-
dc.subjectskin irritation-
dc.subjectsurgical approach-
dc.subjectT shaped locking compression plate-
dc.subjectAdult-
dc.subjectAged-
dc.subjectAnkle Fractures-
dc.subjectBone Plates-
dc.subjectBone Screws-
dc.subjectFemale-
dc.subjectFracture Fixation, Internal-
dc.subjectHumans-
dc.subjectMale-
dc.subjectMiddle Aged-
dc.subjectRetrospective Studies-
dc.titleThe use of T-LCP (locking compression plate) for the treatment of the lateral malleolar fractures-
dc.typeArticle-
dc.contributor.affiliatedAuthorOh, J.-K.-
dc.identifier.doi10.1007/s00590-012-0952-9-
dc.identifier.scopusid2-s2.0-84877129402-
dc.identifier.bibliographicCitationEuropean Journal of Orthopaedic Surgery and Traumatology, v.23, no.2, pp.233 - 237-
dc.relation.isPartOfEuropean Journal of Orthopaedic Surgery and Traumatology-
dc.citation.titleEuropean Journal of Orthopaedic Surgery and Traumatology-
dc.citation.volume23-
dc.citation.number2-
dc.citation.startPage233-
dc.citation.endPage237-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusaged-
dc.subject.keywordPlusAmerican Orthopaedic Foot and Ankle Society score-
dc.subject.keywordPlusankle-
dc.subject.keywordPlusarticle-
dc.subject.keywordPlusclinical article-
dc.subject.keywordPluscompression plate-
dc.subject.keywordPlusdisease classification-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlusfollow up-
dc.subject.keywordPlusfoot radiography-
dc.subject.keywordPlusfracture fixation-
dc.subject.keywordPlusfracture healing-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusjoint mobility-
dc.subject.keywordPluslocking screw-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmalleolus fracture-
dc.subject.keywordPlusoutcome assessment-
dc.subject.keywordPluspriority journal-
dc.subject.keywordPlusradius fracture-
dc.subject.keywordPlusrange of motion-
dc.subject.keywordPlusretrospective study-
dc.subject.keywordPlusscoring system-
dc.subject.keywordPlusskin irritation-
dc.subject.keywordPlussurgical approach-
dc.subject.keywordPlusT shaped locking compression plate-
dc.subject.keywordPlusAdult-
dc.subject.keywordPlusAged-
dc.subject.keywordPlusAnkle Fractures-
dc.subject.keywordPlusBone Plates-
dc.subject.keywordPlusBone Screws-
dc.subject.keywordPlusFemale-
dc.subject.keywordPlusFracture Fixation, Internal-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusMale-
dc.subject.keywordPlusMiddle Aged-
dc.subject.keywordPlusRetrospective Studies-
dc.subject.keywordAuthorAnkle fracture-
dc.subject.keywordAuthorInternal fixation-
dc.subject.keywordAuthorLateral malleolus-
dc.subject.keywordAuthorT-LCP-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jong Keon photo

Oh, Jong Keon
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE