A review of current disinfectants for gastrointestinal endoscopic reprocessing
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, S. | - |
dc.contributor.author | Jang, J.Y. | - |
dc.contributor.author | Koo, J.S. | - |
dc.contributor.author | Park, J.B. | - |
dc.contributor.author | Lim, Y.J. | - |
dc.contributor.author | Hong, S.J. | - |
dc.contributor.author | Kim, S.-W. | - |
dc.contributor.author | Chun, H.J. | - |
dc.date.accessioned | 2021-09-06T09:40:59Z | - |
dc.date.available | 2021-09-06T09:40:59Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 2234-2400 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/105861 | - |
dc.description.abstract | Gastrointestinal endoscopy is gaining popularity for diagnostic and therapeutic purposes. However, concerns over endoscope-related nosocomial infections are increasing, together with interest by the general public in safe and efficient endoscopy. For this reason, reprocessing the gastrointestinal endoscope is an important step for effective performance of endoscopy. Disinfectants are essential to the endoscope reprocessing procedure. Before selecting an appropriate disinfectant, their characteristics, limitations and means of use must be fully understood. Herein, we review the characteristics of several currently available disinfectants, including their uses, potency, advantages, and disadvantages. Most disinfectants can be used to reprocess gastrointestinal endoscopes if the manufacturer's guidelines are followed. The selection and use of a suitable disinfectant depends on the individual circumstances of each endoscopy suite. © 2013 Korean Society of Gastrointestinal Endoscopy. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.title | A review of current disinfectants for gastrointestinal endoscopic reprocessing | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Koo, J.S. | - |
dc.contributor.affiliatedAuthor | Chun, H.J. | - |
dc.identifier.doi | 10.5946/ce.2013.46.4.337 | - |
dc.identifier.scopusid | 2-s2.0-84881059131 | - |
dc.identifier.bibliographicCitation | Clinical Endoscopy, v.46, no.4, pp.337 - 341 | - |
dc.relation.isPartOf | Clinical Endoscopy | - |
dc.citation.title | Clinical Endoscopy | - |
dc.citation.volume | 46 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 337 | - |
dc.citation.endPage | 341 | - |
dc.type.rims | ART | - |
dc.type.docType | Review | - |
dc.identifier.kciid | ART001790501 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Disinfectants | - |
dc.subject.keywordAuthor | Endoscopy | - |
dc.subject.keywordAuthor | Gastrointestinal | - |
dc.subject.keywordAuthor | Reprocessing | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.