Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: A critical appraisal

Full metadata record
DC Field Value Language
dc.contributor.authorDionigi, G.-
dc.contributor.authorDonatini, G.-
dc.contributor.authorBoni, L.-
dc.contributor.authorRausei, S.-
dc.contributor.authorRovera, F.-
dc.contributor.authorTanda, M.L.-
dc.contributor.authorKim, H.Y.-
dc.contributor.authorChiang, F.-Y.-
dc.contributor.authorWu, C.-W.-
dc.contributor.authorMangano, A.-
dc.contributor.authorRulli, F.-
dc.contributor.authorAlesina, P.F.-
dc.contributor.authorDionigi, R.-
dc.date.accessioned2021-09-06T09:53:03Z-
dc.date.available2021-09-06T09:53:03Z-
dc.date.created2021-06-17-
dc.date.issued2013-
dc.identifier.issn1743-9191-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/105934-
dc.description.abstractBackground and Purpose: Intraoperative neuromonitoring (IONM) contributes in several ways to recurrent laryngeal nerve (RLN) protection. Notwithstanding these advantages, surgeons must be aware that the current, intermittent, mode of IONM (I-IONM) has relevant limitations. To overcome these I-IONM limitations, a continuous IONM (C-IONM) technology has been proposed. Methods: A PubMed indexed literature review of the current limitations of I-IONM is presented and a commentary about C-IONM is provided presenting the preliminary results of research on this topic. Main findings: I-IONM, despite the advantages it produces, presents some important limitations; to overcome these drawbacks a C-IONM technology has been introduced. Conclusions: RLN traction injury is still the most common cause of RLN injury and is difficult to avoid with the application of I-IONM in thyroid surgery. C-IONM is useful to prevent the imminent traction injury by detecting progressive decreases in electromyographic amplitude combined with progressive latency increases. C-IONM seems to be a technological improvement. Likely, C-IONM by vagal nerve stimulation should enhance the standardization process, RLN intraoperative information, documentation, protection, training, and research in modern thyroid surgery. Although C-IONM is a promising technology at the cutting edge of research in thyroid surgery, we need more studies to assess in an evidence-based way all its advantages. © 2013 Elsevier Ltd and Surgical Associates Ltd.-
dc.languageEnglish-
dc.language.isoen-
dc.subjectanatomical variation-
dc.subjectelectromyography-
dc.subjectevidence based practice-
dc.subjecthuman-
dc.subjectintraoperative neuromonitoring-
dc.subjectlatent period-
dc.subjectmedical documentation-
dc.subjectMedline-
dc.subjectneuromonitoring-
dc.subjectperoperative care-
dc.subjectpriority journal-
dc.subjectrecurrent laryngeal nerve-
dc.subjectrecurrent laryngeal nerve injury-
dc.subjectreview-
dc.subjectstandardization-
dc.subjectthyroid surgery-
dc.subjectvagus nerve stimulation-
dc.subjectC-IONM-
dc.subjectContinuous intraoperative neuromonitoring-
dc.subjectIONM-
dc.subjectThyroid surgery-
dc.subjectHumans-
dc.subjectMonitoring, Intraoperative-
dc.subjectRecurrent Laryngeal Nerve-
dc.subjectRecurrent Laryngeal Nerve Injuries-
dc.subjectThyroid Gland-
dc.titleContinuous monitoring of the recurrent laryngeal nerve in thyroid surgery: A critical appraisal-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, H.Y.-
dc.identifier.doi10.1016/S1743-9191(13)60014-X-
dc.identifier.scopusid2-s2.0-84891732598-
dc.identifier.bibliographicCitationInternational Journal of Surgery, v.11, no.S1, pp.S44 - S46-
dc.relation.isPartOfInternational Journal of Surgery-
dc.citation.titleInternational Journal of Surgery-
dc.citation.volume11-
dc.citation.numberS1-
dc.citation.startPageS44-
dc.citation.endPageS46-
dc.type.rimsART-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusanatomical variation-
dc.subject.keywordPluselectromyography-
dc.subject.keywordPlusevidence based practice-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusintraoperative neuromonitoring-
dc.subject.keywordPluslatent period-
dc.subject.keywordPlusmedical documentation-
dc.subject.keywordPlusMedline-
dc.subject.keywordPlusneuromonitoring-
dc.subject.keywordPlusperoperative care-
dc.subject.keywordPluspriority journal-
dc.subject.keywordPlusrecurrent laryngeal nerve-
dc.subject.keywordPlusrecurrent laryngeal nerve injury-
dc.subject.keywordPlusreview-
dc.subject.keywordPlusstandardization-
dc.subject.keywordPlusthyroid surgery-
dc.subject.keywordPlusvagus nerve stimulation-
dc.subject.keywordPlusC-IONM-
dc.subject.keywordPlusContinuous intraoperative neuromonitoring-
dc.subject.keywordPlusIONM-
dc.subject.keywordPlusThyroid surgery-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusMonitoring, Intraoperative-
dc.subject.keywordPlusRecurrent Laryngeal Nerve-
dc.subject.keywordPlusRecurrent Laryngeal Nerve Injuries-
dc.subject.keywordPlusThyroid Gland-
dc.subject.keywordAuthorC-IONM-
dc.subject.keywordAuthorContinuous intraoperative neuromonitoring-
dc.subject.keywordAuthorIONM-
dc.subject.keywordAuthorThyroid surgery-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hoon Yub photo

Kim, Hoon Yub
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE