Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Hemorheological changes caused by lead exposure

Full metadata record
DC Field Value Language
dc.contributor.authorKim, C. B.-
dc.contributor.authorShin, Sehyun-
dc.contributor.authorSong, Seok-Heung-
dc.date.accessioned2021-09-06T11:23:04Z-
dc.date.available2021-09-06T11:23:04Z-
dc.date.created2021-06-14-
dc.date.issued2013-
dc.identifier.issn1386-0291-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/106477-
dc.description.abstractLead is a ubiquitous, biohazardous, and toxic heavy metal that induces a broad range of physiological, biochemical, and behavioral dysfunctions. We investigated the effect of lead on hemorheological characteristics, including deformability and aggregation. We found that red blood cell (RBC) deformability was unaffected at low concentrations of lead-rich plasma, but showed a significant decrease at high concentrations even within 1 h of incubation. In addition, apparent alterations in RBC aggregation were observed with an increase in lead concentration and incubation time. These results highlight the influence of lead on hemorheology and microcirculation.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.subjectHEMOLYTIC-ANEMIA-
dc.subjectPROTEIN CORONA-
dc.subjectBLOOD-
dc.subjectERYTHROCYTE-
dc.subjectNANOPARTICLE-
dc.subjectCELLS-
dc.titleHemorheological changes caused by lead exposure-
dc.typeArticle-
dc.contributor.affiliatedAuthorShin, Sehyun-
dc.identifier.doi10.3233/CH-2012-1641-
dc.identifier.scopusid2-s2.0-84891079141-
dc.identifier.wosid000328959000006-
dc.identifier.bibliographicCitationCLINICAL HEMORHEOLOGY AND MICROCIRCULATION, v.55, no.3, pp.341 - 348-
dc.relation.isPartOfCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.citation.titleCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.citation.volume55-
dc.citation.number3-
dc.citation.startPage341-
dc.citation.endPage348-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaHematology-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryHematology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.subject.keywordPlusHEMOLYTIC-ANEMIA-
dc.subject.keywordPlusPROTEIN CORONA-
dc.subject.keywordPlusBLOOD-
dc.subject.keywordPlusERYTHROCYTE-
dc.subject.keywordPlusNANOPARTICLE-
dc.subject.keywordPlusCELLS-
dc.subject.keywordAuthorLead-
dc.subject.keywordAuthortoxicology-
dc.subject.keywordAuthorhemorheology-
dc.subject.keywordAuthordeformability-
dc.subject.keywordAuthoraggregation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Se hyun photo

Shin, Se hyun
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE