Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance characteristics of monoclonal antibodies as recyclable binders to cardiac troponin I

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Dong-Hyung-
dc.contributor.authorPaek, Sung-Ho-
dc.contributor.authorLim, Guei-Sam-
dc.contributor.authorJeon, Jin-Woo-
dc.contributor.authorPaek, Se-Hwan-
dc.date.accessioned2021-09-06T12:13:42Z-
dc.date.available2021-09-06T12:13:42Z-
dc.date.created2021-06-14-
dc.date.issued2012-12-01-
dc.identifier.issn0003-2697-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/106690-
dc.description.abstractAcute myocardial infarction is a typical disorder that requires continuous monitoring for early detection of potential life-threatening situations. To this end, we used different methods to screen for rapidly reversible antibodies, among 22 hybridoma clones, against cardiac troponin I (cTnI), which is a specific marker indicating the disease. The dissociation rates of antibodies were underestimated by up to a factor of 1000 because of bivalent binding when tested with the antigen immobilized on solid surfaces. This effect was also observed in a sandwich immunoassay, in which the detection antibody cross-linked with various antigen molecules already bound to the capture antibody. Although multiple binding events contributed to enhanced detection capability, it was difficult to recycle the immunosensor. We then devised a screening system by arranging the test antibody for the capture binder immobilized on a label-free sensor. This enabled us to select fast reactive antibodies of which one (clone 24) was shown to be recyclable, even in serum-containing medium. Using this antibody, repetitive detection of cTnI with a rapid response time (half-life of dissociation: about 4 min on average) and high detection capability (0.1 ng/ml) was achieved, which is very important for detection in a clinical setting. (c) 2012 Elsevier Inc. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE-
dc.subjectACUTE MYOCARDIAL-INFARCTION-
dc.subjectPROTEIN INTERACTIONS-
dc.subjectBINDING-
dc.subjectIMMOBILIZATION-
dc.subjectKINETICS-
dc.subjectDEGRADATION-
dc.subjectDIAGNOSIS-
dc.subjectELISA-
dc.subjectSERUM-
dc.titlePerformance characteristics of monoclonal antibodies as recyclable binders to cardiac troponin I-
dc.typeArticle-
dc.contributor.affiliatedAuthorPaek, Se-Hwan-
dc.identifier.doi10.1016/j.ab.2012.09.002-
dc.identifier.scopusid2-s2.0-84866853192-
dc.identifier.wosid000310496200003-
dc.identifier.bibliographicCitationANALYTICAL BIOCHEMISTRY, v.431, no.1, pp.11 - 18-
dc.relation.isPartOfANALYTICAL BIOCHEMISTRY-
dc.citation.titleANALYTICAL BIOCHEMISTRY-
dc.citation.volume431-
dc.citation.number1-
dc.citation.startPage11-
dc.citation.endPage18-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryBiochemistry & Molecular Biology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusACUTE MYOCARDIAL-INFARCTION-
dc.subject.keywordPlusPROTEIN INTERACTIONS-
dc.subject.keywordPlusBINDING-
dc.subject.keywordPlusIMMOBILIZATION-
dc.subject.keywordPlusKINETICS-
dc.subject.keywordPlusDEGRADATION-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusELISA-
dc.subject.keywordPlusSERUM-
dc.subject.keywordAuthorRapidly reactive antibodies-
dc.subject.keywordAuthorRecycling of antibody as capture binder-
dc.subject.keywordAuthorUnattended monitoring of AMI-
dc.subject.keywordAuthorMyoglobin and cardiac troponin I as reinfarction markers-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE