Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning

Full metadata record
DC Field Value Language
dc.contributor.authorColafranceschi, S.-
dc.contributor.authorBenussi, L.-
dc.contributor.authorBianco, S.-
dc.contributor.authorPassamonti, L.-
dc.contributor.authorPiccolo, D.-
dc.contributor.authorPierluigi, D.-
dc.contributor.authorRusso, A.-
dc.contributor.authorSaviano, G.-
dc.contributor.authorVendittozzi, C.-
dc.contributor.authorAbbrescia, M.-
dc.contributor.authorAleksandrov, A.-
dc.contributor.authorBerzano, U.-
dc.contributor.authorCalabria, C.-
dc.contributor.authorCarrillo, C.-
dc.contributor.authorColaleo, A.-
dc.contributor.authorGenchev, V.-
dc.contributor.authorIaydjiev, P.-
dc.contributor.authorKang, M.-
dc.contributor.authorLee, K. S.-
dc.contributor.authorLoddo, F.-
dc.contributor.authorPark, S. K.-
dc.contributor.authorPugliese, G.-
dc.contributor.authorMaggi, M.-
dc.contributor.authorShin, S.-
dc.contributor.authorRodozov, M.-
dc.contributor.authorShopova, M.-
dc.contributor.authorSultanov, G.-
dc.contributor.authorVerwillingen, P.-
dc.date.accessioned2021-09-06T12:45:19Z-
dc.date.available2021-09-06T12:45:19Z-
dc.date.created2021-06-14-
dc.date.issued2012-12-
dc.identifier.issn1748-0221-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/106866-
dc.description.abstractThe Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.subjectRESISTIVE PLATE CHAMBERS-
dc.subjectCOSMIC-RAYS-
dc.titlePerformance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, S. K.-
dc.identifier.doi10.1088/1748-0221/7/12/P12004-
dc.identifier.scopusid2-s2.0-84875513837-
dc.identifier.wosid000312962500035-
dc.identifier.bibliographicCitationJOURNAL OF INSTRUMENTATION, v.7-
dc.relation.isPartOfJOURNAL OF INSTRUMENTATION-
dc.citation.titleJOURNAL OF INSTRUMENTATION-
dc.citation.volume7-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusRESISTIVE PLATE CHAMBERS-
dc.subject.keywordPlusCOSMIC-RAYS-
dc.subject.keywordAuthorMuon spectrometers-
dc.subject.keywordAuthorGaseous detectors-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE