Tests of multigap RPCs for high-eta triggers in CMS
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, K. S. | - |
dc.contributor.author | Aleksandrov, A. | - |
dc.contributor.author | Berzano, U. | - |
dc.contributor.author | Calabria, C. | - |
dc.contributor.author | Carrillo, C. | - |
dc.contributor.author | Colaleo, A. | - |
dc.contributor.author | Genchev, V. | - |
dc.contributor.author | Iaydjiev, P. | - |
dc.contributor.author | Jeng, Y. G. | - |
dc.contributor.author | Kang, M. | - |
dc.contributor.author | Loddo, F. | - |
dc.contributor.author | Maggi, M. | - |
dc.contributor.author | Park, S. K. | - |
dc.contributor.author | Pugliese, G. | - |
dc.contributor.author | Rodozov, M. | - |
dc.contributor.author | Shin, S. S. | - |
dc.contributor.author | Shopova, M. | - |
dc.contributor.author | Sim, K. S. | - |
dc.contributor.author | Sultanov, G. | - |
dc.contributor.author | Verwilligen, P. | - |
dc.date.accessioned | 2021-09-06T14:43:54Z | - |
dc.date.available | 2021-09-06T14:43:54Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2012-10 | - |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/107242 | - |
dc.description.abstract | In this paper, we report a systematic study of multigap Resistive Plate Chambers (RPCs) for high-eta triggers in CMS. Prototype RPC modules with four- and six-gap structures have been constructed with phenolic high-pressure-laminated (HPL) plates and tested with cosmic muons and gamma rays irradiated from a 200-mCi Cs-137 source. The detector characteristics of the prototype multigap RPCs were compared with those of the double-gap RPCs currently used in the CMS experiment at LHC. The mean values for detector charges of cosmic-muon signals drawn in the four- and six-gap RPCs for the efficiency values in the middle of the plateau were about 1.5 and 0.9 pC, respectively, when digitized with charge thresholds of 150 and 100 fC, respectively. They were respectively about one third and one fifth of that drawn in the current CMS double-gap RPC with a charge threshold of 200 fC. We concluded from the current R&D that use of the current phenolic-HPL multigap RPCs is advantageous to the high-eta triggers in CMS in virtue of the smaller detector pulses. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | RESISTIVE PLATE CHAMBER | - |
dc.subject | AVALANCHE MODE | - |
dc.subject | IRRADIATION | - |
dc.subject | PERFORMANCE | - |
dc.subject | SIMULATION | - |
dc.subject | CMS/LHC | - |
dc.title | Tests of multigap RPCs for high-eta triggers in CMS | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, K. S. | - |
dc.contributor.affiliatedAuthor | Park, S. K. | - |
dc.identifier.doi | 10.1088/1748-0221/7/10/P10009 | - |
dc.identifier.scopusid | 2-s2.0-84868273993 | - |
dc.identifier.wosid | 000310834800019 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INSTRUMENTATION, v.7 | - |
dc.relation.isPartOf | JOURNAL OF INSTRUMENTATION | - |
dc.citation.title | JOURNAL OF INSTRUMENTATION | - |
dc.citation.volume | 7 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | RESISTIVE PLATE CHAMBER | - |
dc.subject.keywordPlus | AVALANCHE MODE | - |
dc.subject.keywordPlus | IRRADIATION | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | SIMULATION | - |
dc.subject.keywordPlus | CMS/LHC | - |
dc.subject.keywordAuthor | Gaseous detectors | - |
dc.subject.keywordAuthor | Particle tracking detectors (Gaseous detectors) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.