Microcones configured with full-bridge circuits
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoon, Hyung-Koo | - |
dc.contributor.author | Lee, Jong-Sub | - |
dc.date.accessioned | 2021-09-06T14:53:10Z | - |
dc.date.available | 2021-09-06T14:53:10Z | - |
dc.date.created | 2021-06-15 | - |
dc.date.issued | 2012-10 | - |
dc.identifier.issn | 0267-7261 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/107296 | - |
dc.description.abstract | Small-diameter microcones have been widely used for the characterisation of soil properties in the field and in the calibration chamber because the smaller probe may require a smaller penetrometer capacity and a smaller calibration chamber. As the cone size decreases, the area required for the installation of the strain gauges also decreases, and thus, the half-bridge circuit has been generally adopted. The objective of this study is the development and application of a microcone configured with a full-bridge circuit instead of the half-bridge circuit for the measurement of the cone tip resistance and sleeve friction. The diameter of the microcone is designed to be D = 15 mm, and thus, the projected area is 1.76 cm(2). The full-bridge circuit in the microcone is configured by extending the rod behind the connection part for the installation of four strain gauges. Two strain gauges are installed in the loading part, and two strain gauges are installed in the extended rod. In addition, the half-bridge circuit is also used for comparison of the cone tip resistance and sleeve friction in both circuits. The advantages of the microcone with the extended rod are verified through a theoretical background study and through experimental studies of various parameters, including temperature calibration, stress calibration, and densification monitoring. The test results show that the extended rod-type microcone with a full-bridge is less affected by environmental effects and produces better linearity between the output voltage and the stress. In addition, the full-bridge circuit yields more reasonable and reliable cone tip resistance and sleeve friction values than the half-bridge circuit. This study demonstrates that the extended rod-type microcone may be an alternative choice for the configuration of the full-bridge for better resistance measurements. (C) 2012 Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCI LTD | - |
dc.subject | LIQUEFACTION RESISTANCE | - |
dc.subject | CPT | - |
dc.subject | PENETROMETER | - |
dc.subject | PERFORMANCE | - |
dc.subject | PIEZOCONES | - |
dc.subject | SOILS | - |
dc.title | Microcones configured with full-bridge circuits | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jong-Sub | - |
dc.identifier.doi | 10.1016/j.soildyn.2012.05.013 | - |
dc.identifier.scopusid | 2-s2.0-84861988475 | - |
dc.identifier.wosid | 000306765800011 | - |
dc.identifier.bibliographicCitation | SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, v.41, pp.119 - 127 | - |
dc.relation.isPartOf | SOIL DYNAMICS AND EARTHQUAKE ENGINEERING | - |
dc.citation.title | SOIL DYNAMICS AND EARTHQUAKE ENGINEERING | - |
dc.citation.volume | 41 | - |
dc.citation.startPage | 119 | - |
dc.citation.endPage | 127 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Geology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Geological | - |
dc.relation.journalWebOfScienceCategory | Geosciences, Multidisciplinary | - |
dc.subject.keywordPlus | LIQUEFACTION RESISTANCE | - |
dc.subject.keywordPlus | CPT | - |
dc.subject.keywordPlus | PENETROMETER | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | PIEZOCONES | - |
dc.subject.keywordPlus | SOILS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.