Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimal carbon dioxide insufflation pressure during robot-assisted thyroidectomy in patients with various benign and malignant thyroid diseases

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hoon Yub-
dc.contributor.authorChoi, Yoon Ji-
dc.contributor.authorYu, Hae-Na-
dc.contributor.authorYoon, Seung Zhoo-
dc.date.accessioned2021-09-06T15:16:20Z-
dc.date.available2021-09-06T15:16:20Z-
dc.date.created2021-06-15-
dc.date.issued2012-09-27-
dc.identifier.issn1477-7819-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/107430-
dc.description.abstractBackground: Currently, data are not available concerning a safe insufflation pressure that provides a proper view of the surgical field without adverse metabolic and hemodynamic changes in humans undergoing the robot-assisted thyroidectomy bilateral axillo-breast approach (BABA) using the da Vinci robotic surgical system. The purpose of this study was to determine the optimal carbon dioxide (CO2) insufflation pressure in patients with various benign and malignant thyroid diseases when using the da Vinci robotic surgical system. Methods: A total of 32 patients underwent thyroid surgery at 6 (n = 15), 9 (n = 15), and 12 (n = 2) mmHg. The partial pressure of carbon dioxide (PaCO2), pH, cardiac output, heart rate, and mean arterial pressure were measured at baseline, 30 min and 1, 1.5, and 2 hours after CO2 insufflation, and 30 min after desufflation. Results: CO2 insufflation of 12 mmHg caused severe facial subcutaneous emphysema, hypercarbia, and acidosis during robot-assisted thyroidectomy with BABA. The study was stopped before completion for the patients' safety in accordance with the study protocol. Applying 6- or 9-mmHg of CO2 insufflation pressure caused increases in PaCO2 and decreases in arterial pH. However, vital signs were stable and pH and PaCO2 were within the physiologic range during the surgery in the 6- and 9-mmHg groups. Conclusions: We propose that a CO2 insufflation pressure under 10 mmHg in robot-assisted thyroidectomy with BABA is the optimal insufflation pressure for patient safety.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBIOMED CENTRAL LTD-
dc.subjectPULMONARY-ARTERY CATHETERS-
dc.subjectPULSE-CONTOUR ANALYSIS-
dc.subjectAXILLO-BREAST APPROACH-
dc.subjectCARDIAC-OUTPUT-
dc.subjectCONTROLLED-TRIAL-
dc.subjectSURGERY-
dc.subjectPARATHYROIDECTOMY-
dc.subjectTHERMODILUTION-
dc.subjectHYPERCARBIA-
dc.subjectSYSTEM-
dc.titleOptimal carbon dioxide insufflation pressure during robot-assisted thyroidectomy in patients with various benign and malignant thyroid diseases-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Hoon Yub-
dc.contributor.affiliatedAuthorChoi, Yoon Ji-
dc.contributor.affiliatedAuthorYoon, Seung Zhoo-
dc.identifier.doi10.1186/1477-7819-10-202-
dc.identifier.scopusid2-s2.0-84866711518-
dc.identifier.wosid000311543100002-
dc.identifier.bibliographicCitationWORLD JOURNAL OF SURGICAL ONCOLOGY, v.10-
dc.relation.isPartOfWORLD JOURNAL OF SURGICAL ONCOLOGY-
dc.citation.titleWORLD JOURNAL OF SURGICAL ONCOLOGY-
dc.citation.volume10-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOncology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOncology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusPULMONARY-ARTERY CATHETERS-
dc.subject.keywordPlusPULSE-CONTOUR ANALYSIS-
dc.subject.keywordPlusAXILLO-BREAST APPROACH-
dc.subject.keywordPlusCARDIAC-OUTPUT-
dc.subject.keywordPlusCONTROLLED-TRIAL-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusPARATHYROIDECTOMY-
dc.subject.keywordPlusTHERMODILUTION-
dc.subject.keywordPlusHYPERCARBIA-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorBenign and malignant thyroid diseases-
dc.subject.keywordAuthorBilateral axillo-breast approach-
dc.subject.keywordAuthorDa Vinci-
dc.subject.keywordAuthorCarbon dioxide insufflation-
dc.subject.keywordAuthorPressure-
dc.subject.keywordAuthorRobot-assisted thyroid surgery-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Seung Zhoo photo

Yoon, Seung Zhoo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE