Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Early Fibrovascular Proliferation According to Orbital Implant in Orbital Floor Fracture Reconstruction

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Hwa-
dc.contributor.authorBaek, Sehyun-
dc.date.accessioned2021-09-06T16:15:59Z-
dc.date.available2021-09-06T16:15:59Z-
dc.date.created2021-06-18-
dc.date.issued2012-09-
dc.identifier.issn1049-2275-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/107641-
dc.description.abstractBackgrounds: Although reports of successful treatment results of orbital fractures are numerous, histopathologic changes associated with favorable outcomes have not yet been established. The purpose of this study was to observe fibrovascular ingrowth into implants, fibrovascularization, and inflammatory reactions in surface tissues of implants in an animal model of orbital floor fractures. Methods: Twenty-four New Zealand white rabbits were used in the study. A standardized 6-mm-diameter defect was made bilaterally in the maxillary sinuses to include bone and mucosa, and an 8 x 8-mm alloplastic implant was inserted. In the control group, a bone defect was made, but no implant was inserted. Two different implant materials 1 mm in width were used: porous high-density polyethylene (Medpor, group A) and absorbable copolymer (Macropore, group B). The implants were harvested at 1, 2, and 6 weeks after implantation. Hematoxylin-eosin stains and immunohistochemical studies of basic fibroblast growth factor (bFGF) and CD31 (platelet/endothelial cell adhesion molecule) were conducted. Results: Full-thickness fibrovascular ingrowth into the implants was observed in group A after 2 weeks, but there was no fibrovascular ingrowth into the implant in group B. The inflammatory reactions between the implant and the connective tissue were grade 2 at 1 week and grade 1 at 2 and 6 weeks in both groups. The bFGF indexes in fibrovascular tissue growing into the nonabsorbable porous polyethylene implants (group A-1) were 0.3 at 1 week, 2.3 at 2 weeks, and 3.0 at 6 weeks. The bFGF indexes at the surface tissues of the implant in the nonabsorbable porous polyethylene implants (Medpor, group A-2) and group B were 1.0 and 1.8 at 1 week, 2.5 and 2.8 at 2 weeks, and 3.0 and 3.0 at 6 weeks. Expressions of CD31 in group A-1 were 3.8 at 1 week, 6.0 at 2 weeks, and 20.3 at 6 weeks. Expressions of CD31 in group A-2 and group B were 19.8 and 23.3 at 1 week, 38.0 and 49.3 at 2 weeks, and 64.3 and 72.0 at 6 weeks. Conclusions: Because there was no fibrovascular ingrowth into the absorbable copolymer implant, such implants may be advantageous in orbital wall fractures with exposures of extraocular muscle. However, the possibility of migration and extrusion of the implant cannot be excluded because there was no fibrovascular ingrowth into the absorbable copolymer implants. Therefore, nonabsorbable porous polyethylene implants are better suited for use in orbital wall fractures when there is concern about implant migration and extrusion during the early postoperative period and large orbital wall fractures.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.subjectFIBROBLAST-GROWTH-FACTOR-
dc.subjectPOROUS POLYETHYLENE-
dc.subjectIN-VITRO-
dc.subjectPOLY(L-LACTIDE) IMPLANTS-
dc.subjectDEGRADATION-
dc.subjectMANAGEMENT-
dc.subjectANGIOGENESIS-
dc.subjectREPAIR-
dc.subjectTUMOR-
dc.subjectGRAFT-
dc.titleComparison of Early Fibrovascular Proliferation According to Orbital Implant in Orbital Floor Fracture Reconstruction-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Hwa-
dc.contributor.affiliatedAuthorBaek, Sehyun-
dc.identifier.doi10.1097/SCS.0b013e31825a61de-
dc.identifier.scopusid2-s2.0-84867819946-
dc.identifier.wosid000309547200129-
dc.identifier.bibliographicCitationJOURNAL OF CRANIOFACIAL SURGERY, v.23, no.5, pp.1518 - 1523-
dc.relation.isPartOfJOURNAL OF CRANIOFACIAL SURGERY-
dc.citation.titleJOURNAL OF CRANIOFACIAL SURGERY-
dc.citation.volume23-
dc.citation.number5-
dc.citation.startPage1518-
dc.citation.endPage1523-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusFIBROBLAST-GROWTH-FACTOR-
dc.subject.keywordPlusPOROUS POLYETHYLENE-
dc.subject.keywordPlusIN-VITRO-
dc.subject.keywordPlusPOLY(L-LACTIDE) IMPLANTS-
dc.subject.keywordPlusDEGRADATION-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusANGIOGENESIS-
dc.subject.keywordPlusREPAIR-
dc.subject.keywordPlusTUMOR-
dc.subject.keywordPlusGRAFT-
dc.subject.keywordAuthorAbsorbable copolymer implant (Macropore)-
dc.subject.keywordAuthorbasic fibrovascular growth factor (bFGF)-
dc.subject.keywordAuthorCD31 (platelet endothelial cell adhesion molecule [PECAM-1])-
dc.subject.keywordAuthorNonabsorbable porous polyethylene implant (Medpor)-
dc.subject.keywordAuthororbital wall fracture-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Baek, Se Hyun photo

Baek, Se Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE