Reliability of a PowerPoint Method for Wear Measurement After Total Hip Arthroplasty A Retrieval Study Using 3-Dimensional Laser Scanning
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yun, Ho Hyun | - |
dc.contributor.author | Shon, Won Yong | - |
dc.contributor.author | Yoon, Jung Ro | - |
dc.contributor.author | Yang, Jae-Hyuk | - |
dc.contributor.author | Lim, Deuk-Soo | - |
dc.date.accessioned | 2021-09-06T16:19:27Z | - |
dc.date.available | 2021-09-06T16:19:27Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2012-09 | - |
dc.identifier.issn | 0883-5403 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/107660 | - |
dc.description.abstract | The purpose of this study was to evaluate the reliability of the Power Point (PP) (2007 Version; Microsoft, Redmond, Wash) method for measuring polyethylene liner wear after total hip arthroplasty. Seventeen retrieved polyethylene liners were included in this study. Wear volumes were calculated using the PP, the Dorr and Wan, and 3-dimensional (3D) laser scanning methods. Spearman correlation coefficients for wear volume results indicated strong correlations between the PP and 3D laser scanning methods (range, 0.89-0.93). On the other hand, Spearman correlation analysis revealed only moderate correlations between the Dorr and Wan and 3D laser scanning methods (range, 0.67-0.77). The PP method can be used to monitor linear wear after total hip arthroplasty and could serve as an alternative method when computerized methods are not available. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS | - |
dc.subject | CROSS-LINKED POLYETHYLENE | - |
dc.subject | BACKED ACETABULAR CUPS | - |
dc.subject | RADIOGRAPHIC MEASUREMENT | - |
dc.subject | FEMORAL-HEAD | - |
dc.subject | VOLUMETRIC WEAR | - |
dc.subject | PENETRATION | - |
dc.subject | REPLACEMENT | - |
dc.subject | COMPONENTS | - |
dc.subject | VALIDATION | - |
dc.subject | ACCURACY | - |
dc.title | Reliability of a PowerPoint Method for Wear Measurement After Total Hip Arthroplasty A Retrieval Study Using 3-Dimensional Laser Scanning | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Shon, Won Yong | - |
dc.identifier.doi | 10.1016/j.arth.2011.12.025 | - |
dc.identifier.scopusid | 2-s2.0-84865346022 | - |
dc.identifier.wosid | 000308618100019 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ARTHROPLASTY, v.27, no.8, pp.1530 - 1537 | - |
dc.relation.isPartOf | JOURNAL OF ARTHROPLASTY | - |
dc.citation.title | JOURNAL OF ARTHROPLASTY | - |
dc.citation.volume | 27 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 1530 | - |
dc.citation.endPage | 1537 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.subject.keywordPlus | CROSS-LINKED POLYETHYLENE | - |
dc.subject.keywordPlus | BACKED ACETABULAR CUPS | - |
dc.subject.keywordPlus | RADIOGRAPHIC MEASUREMENT | - |
dc.subject.keywordPlus | FEMORAL-HEAD | - |
dc.subject.keywordPlus | VOLUMETRIC WEAR | - |
dc.subject.keywordPlus | PENETRATION | - |
dc.subject.keywordPlus | REPLACEMENT | - |
dc.subject.keywordPlus | COMPONENTS | - |
dc.subject.keywordPlus | VALIDATION | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordAuthor | hip | - |
dc.subject.keywordAuthor | total hip arthroplasty | - |
dc.subject.keywordAuthor | wear | - |
dc.subject.keywordAuthor | wear measurement | - |
dc.subject.keywordAuthor | PowerPoint method | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.