Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reliability of a PowerPoint Method for Wear Measurement After Total Hip Arthroplasty A Retrieval Study Using 3-Dimensional Laser Scanning

Full metadata record
DC Field Value Language
dc.contributor.authorYun, Ho Hyun-
dc.contributor.authorShon, Won Yong-
dc.contributor.authorYoon, Jung Ro-
dc.contributor.authorYang, Jae-Hyuk-
dc.contributor.authorLim, Deuk-Soo-
dc.date.accessioned2021-09-06T16:19:27Z-
dc.date.available2021-09-06T16:19:27Z-
dc.date.created2021-06-18-
dc.date.issued2012-09-
dc.identifier.issn0883-5403-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/107660-
dc.description.abstractThe purpose of this study was to evaluate the reliability of the Power Point (PP) (2007 Version; Microsoft, Redmond, Wash) method for measuring polyethylene liner wear after total hip arthroplasty. Seventeen retrieved polyethylene liners were included in this study. Wear volumes were calculated using the PP, the Dorr and Wan, and 3-dimensional (3D) laser scanning methods. Spearman correlation coefficients for wear volume results indicated strong correlations between the PP and 3D laser scanning methods (range, 0.89-0.93). On the other hand, Spearman correlation analysis revealed only moderate correlations between the Dorr and Wan and 3D laser scanning methods (range, 0.67-0.77). The PP method can be used to monitor linear wear after total hip arthroplasty and could serve as an alternative method when computerized methods are not available.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherCHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS-
dc.subjectCROSS-LINKED POLYETHYLENE-
dc.subjectBACKED ACETABULAR CUPS-
dc.subjectRADIOGRAPHIC MEASUREMENT-
dc.subjectFEMORAL-HEAD-
dc.subjectVOLUMETRIC WEAR-
dc.subjectPENETRATION-
dc.subjectREPLACEMENT-
dc.subjectCOMPONENTS-
dc.subjectVALIDATION-
dc.subjectACCURACY-
dc.titleReliability of a PowerPoint Method for Wear Measurement After Total Hip Arthroplasty A Retrieval Study Using 3-Dimensional Laser Scanning-
dc.typeArticle-
dc.contributor.affiliatedAuthorShon, Won Yong-
dc.identifier.doi10.1016/j.arth.2011.12.025-
dc.identifier.scopusid2-s2.0-84865346022-
dc.identifier.wosid000308618100019-
dc.identifier.bibliographicCitationJOURNAL OF ARTHROPLASTY, v.27, no.8, pp.1530 - 1537-
dc.relation.isPartOfJOURNAL OF ARTHROPLASTY-
dc.citation.titleJOURNAL OF ARTHROPLASTY-
dc.citation.volume27-
dc.citation.number8-
dc.citation.startPage1530-
dc.citation.endPage1537-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.subject.keywordPlusCROSS-LINKED POLYETHYLENE-
dc.subject.keywordPlusBACKED ACETABULAR CUPS-
dc.subject.keywordPlusRADIOGRAPHIC MEASUREMENT-
dc.subject.keywordPlusFEMORAL-HEAD-
dc.subject.keywordPlusVOLUMETRIC WEAR-
dc.subject.keywordPlusPENETRATION-
dc.subject.keywordPlusREPLACEMENT-
dc.subject.keywordPlusCOMPONENTS-
dc.subject.keywordPlusVALIDATION-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordAuthorhip-
dc.subject.keywordAuthortotal hip arthroplasty-
dc.subject.keywordAuthorwear-
dc.subject.keywordAuthorwear measurement-
dc.subject.keywordAuthorPowerPoint method-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE