Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, Suchul | - |
dc.contributor.author | Lee, Boram | - |
dc.contributor.author | Shin, Gwisoon | - |
dc.contributor.author | Choi, Jonghak | - |
dc.contributor.author | Kim, Jungmin | - |
dc.contributor.author | Park, Changseo | - |
dc.contributor.author | Park, Hyok | - |
dc.contributor.author | Lee, Kisung | - |
dc.contributor.author | Kim, Youhyun | - |
dc.date.accessioned | 2021-09-06T17:57:52Z | - |
dc.date.available | 2021-09-06T17:57:52Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2012-07 | - |
dc.identifier.issn | 0144-8420 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/107988 | - |
dc.description.abstract | In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dosearea product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm(2), respectively, were measured. In panoramic, cephalometric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm(2) (16 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extraoral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extraoral radiography. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | OXFORD UNIV PRESS | - |
dc.subject | RADIATION-EXPOSURE | - |
dc.title | Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Jonghak | - |
dc.contributor.affiliatedAuthor | Kim, Jungmin | - |
dc.contributor.affiliatedAuthor | Lee, Kisung | - |
dc.contributor.affiliatedAuthor | Kim, Youhyun | - |
dc.identifier.doi | 10.1093/rpd/ncr439 | - |
dc.identifier.scopusid | 2-s2.0-84864982137 | - |
dc.identifier.wosid | 000306646100016 | - |
dc.identifier.bibliographicCitation | RADIATION PROTECTION DOSIMETRY, v.150, no.4, pp.523 - 531 | - |
dc.relation.isPartOf | RADIATION PROTECTION DOSIMETRY | - |
dc.citation.title | RADIATION PROTECTION DOSIMETRY | - |
dc.citation.volume | 150 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 523 | - |
dc.citation.endPage | 531 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | RADIATION-EXPOSURE | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.