Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Eye tracking and gating system for proton therapy of orbital tumors

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Dongho-
dc.contributor.authorYoo, Seung Hoon-
dc.contributor.authorMoon, Sung Ho-
dc.contributor.authorYoon, Myonggeun-
dc.contributor.authorLee, Se Byeong-
dc.contributor.authorPark, Sung Yong-
dc.date.accessioned2021-09-06T18:24:10Z-
dc.date.available2021-09-06T18:24:10Z-
dc.date.created2021-06-18-
dc.date.issued2012-07-
dc.identifier.issn0094-2405-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/108106-
dc.description.abstractPurpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729708]-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAMER ASSOC PHYSICISTS MEDICINE AMER INST PHYSICS-
dc.subjectUVEAL MELANOMA-
dc.subjectSTEREOTACTIC RADIOTHERAPY-
dc.subjectBEAM RADIOTHERAPY-
dc.subjectPLAQUE RADIOTHERAPY-
dc.subjectCHOROIDAL MELANOMA-
dc.subjectCOMPLICATIONS-
dc.subjectIRRADIATION-
dc.subjectSURVIVAL-
dc.titleEye tracking and gating system for proton therapy of orbital tumors-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Myonggeun-
dc.identifier.doi10.1118/1.4729708-
dc.identifier.scopusid2-s2.0-84864227793-
dc.identifier.wosid000306893000024-
dc.identifier.bibliographicCitationMEDICAL PHYSICS, v.39, no.7, pp.4265 - 4273-
dc.relation.isPartOfMEDICAL PHYSICS-
dc.citation.titleMEDICAL PHYSICS-
dc.citation.volume39-
dc.citation.number7-
dc.citation.startPage4265-
dc.citation.endPage4273-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusUVEAL MELANOMA-
dc.subject.keywordPlusSTEREOTACTIC RADIOTHERAPY-
dc.subject.keywordPlusBEAM RADIOTHERAPY-
dc.subject.keywordPlusPLAQUE RADIOTHERAPY-
dc.subject.keywordPlusCHOROIDAL MELANOMA-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusIRRADIATION-
dc.subject.keywordPlusSURVIVAL-
dc.subject.keywordAuthorproton-
dc.subject.keywordAuthoreye tracking-
dc.subject.keywordAuthorproton gating-
dc.subject.keywordAuthororbital tumors-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads