Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the Accuracy of Different Combinations of Automatic Registration Selection Factors in Obtaining Tomotherapy Megavoltage Computed Tomography Images

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Suk-
dc.contributor.authorCao, Yuan Jie-
dc.contributor.authorShim, Jang Bo-
dc.contributor.authorChang, Kyung Hwan-
dc.contributor.authorYang, Dae Sik-
dc.contributor.authorPark, Young Je-
dc.contributor.authorYoon, Won Seob-
dc.contributor.authorKim, Chul Yong-
dc.contributor.authorCho, Kwang Hwan-
dc.contributor.authorMin, C. K.-
dc.contributor.authorKim, Y. H.-
dc.date.accessioned2021-09-06T18:56:36Z-
dc.date.available2021-09-06T18:56:36Z-
dc.date.created2021-06-18-
dc.date.issued2012-06-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/108188-
dc.description.abstractThe purpose of our study is to find the potential best options for the registration selection parameters when performing automatic registration between kilovoltage computed tomography (KVCT) and megavoltage computed tomography (MVCT) images in helical tomotherapy. We compared nine different combinations of automatic registration parameters, including technique and resolution in automatic registration control and tomoimage filtering in scan image control. In the phantom study, we compared the translational and the rotational adjustments between the original position (lateral 0 cm; longitudinal 0 cm; vertical 0 cm) and the manually moved position (lateral 1 cm; longitudinal 1 cm; vertical 1 cm). In the patient study, we compared translational (lateral, longitudinal, vertical) and rotational (pitch, roll, yaw) adjustments between the KVCT and the MVCT images for different anatomic treatment sites. The ranges of translational and rotational displacements in the phantom study were 14.87 +/- 0.12 similar to 15.70 +/- 0.04 mm and 0 degrees similar to 1.03 +/- 0.58 degrees, respectively. In cranial cases, the ranges of translational and rotational root-mean-square values were 4.3 +/- 0.4 mm similar to 5.3 +/- 0.6 mm, and 0.3 +/- 0.3 degrees similar to 0.7 +/- 0.4 degrees, respectively. In the extra cranial cases, the ranges of translational and rotational root-mean-square values were 14.1 +/- 3.6 mm similar to 16.1 +/- 2.5 mm, and 0.5 +/- 0.3 degrees similar to 1.0 +/- 0.5 degrees, respectively. We found that the combination of "full image - super fine" could minimize the mechanical deviations in the cranial case, and that both the combinations of "bone tissue - super fine" and "full image - super fine" were the best options in extra cranial cases.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectMODULATED RADIATION-THERAPY-
dc.subjectGUIDED HELICAL TOMOTHERAPY-
dc.subjectCONFORMAL RADIOTHERAPY-
dc.subjectCT IMAGES-
dc.subjectHEAD-
dc.subjectIMPLEMENTATION-
dc.subjectLOCALIZATION-
dc.subjectVERIFICATION-
dc.subjectDELIVERY-
dc.subjectGUIDANCE-
dc.titleEvaluation of the Accuracy of Different Combinations of Automatic Registration Selection Factors in Obtaining Tomotherapy Megavoltage Computed Tomography Images-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Suk-
dc.contributor.affiliatedAuthorYang, Dae Sik-
dc.contributor.affiliatedAuthorYoon, Won Seob-
dc.contributor.affiliatedAuthorKim, Chul Yong-
dc.identifier.doi10.3938/jkps.60.1961-
dc.identifier.scopusid2-s2.0-84863611363-
dc.identifier.wosid000305223000025-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.60, no.11, pp.1961 - 1966-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume60-
dc.citation.number11-
dc.citation.startPage1961-
dc.citation.endPage1966-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001665940-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusMODULATED RADIATION-THERAPY-
dc.subject.keywordPlusGUIDED HELICAL TOMOTHERAPY-
dc.subject.keywordPlusCONFORMAL RADIOTHERAPY-
dc.subject.keywordPlusCT IMAGES-
dc.subject.keywordPlusHEAD-
dc.subject.keywordPlusIMPLEMENTATION-
dc.subject.keywordPlusLOCALIZATION-
dc.subject.keywordPlusVERIFICATION-
dc.subject.keywordPlusDELIVERY-
dc.subject.keywordPlusGUIDANCE-
dc.subject.keywordAuthorTomotherapy-
dc.subject.keywordAuthorMVCT-
dc.subject.keywordAuthorAutomatic registration control-
dc.subject.keywordAuthorScan image control-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chul Yong photo

Kim, Chul Yong
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE