Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Impact of Heterogeneous Overlapping Drug-Eluting Stents on the Arterial Responses of Rabbit Iliac Arteries: A Comparison With Overlapping Bare Metal Stents

Full metadata record
DC Field Value Language
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorChen, Kang-Yin-
dc.contributor.authorOh, Dong Joo-
dc.contributor.authorLi, Yong-Jian-
dc.contributor.authorJin, Zhe-
dc.contributor.authorPoddar, Kanhaiya Lal-
dc.contributor.authorRamasamy, Sureshkumar-
dc.contributor.authorMinami, Yoshiyasu-
dc.contributor.authorElnagar, Amro-
dc.contributor.authorChoi, Byoung Geol-
dc.contributor.authorHong, Sang Pyo-
dc.contributor.authorCheon, Byoung Won-
dc.contributor.authorMoon, Sang Ki-
dc.contributor.authorIm, Sung Il-
dc.contributor.authorKim, Sun Won-
dc.contributor.authorNa, Jin Oh-
dc.contributor.authorChoi, Cheol Ung-
dc.contributor.authorLim, Hong Euy-
dc.contributor.authorKim, Jin Won-
dc.contributor.authorKim, Eung Ju-
dc.contributor.authorHan, Seong Woo-
dc.contributor.authorPark, Chang Gyu-
dc.contributor.authorSeo, Hong Seog-
dc.contributor.authorKim, Jung Ha-
dc.contributor.authorHong, Young Joon-
dc.contributor.authorJeong, Myung Ho-
dc.date.accessioned2021-09-06T19:20:10Z-
dc.date.available2021-09-06T19:20:10Z-
dc.date.created2021-06-18-
dc.date.issued2012-06-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/108312-
dc.description.abstractBackground and Objectives: Although the use of heterogeneous overlapping drug-eluting stents (DES) is not uncommon in clinical practice, whether the implantation sequences of heterogeneous DES will influence the endothelialization or arterial responses differently remains unclear. Materials and Methods: Twenty-one rabbits were randomized to receive overlapping stents in the iliac artery for 3 months {distal sirolimus-eluting stent (SES, Cypher (TM))+ proximal paclitaxel-eluting stent (PES, Taxus (TM)) (C+T, n=7), distal Taxus+proximal Cypher (T+C, n= 7) and bare metal stent (BMS)+ BMS (B+B, n= 7)}. Endothelial function was evaluated by the acetylcholine provocation test during follow-up angiography. Histopathological changes in proximal, overlapped, and distal stented segments were evaluated. Results: Although the overall angiographic outcomes were comparable, late loss (mm) in the distal stented segment was higher in the B+B (0.39 +/- 0.07) and C+T (0.40 +/- 0.20) than that in the T+C (0.06 +/- 0.02) group (p<0.001). The incidence of acetylcholine-induced spasm was higher in the DES groups compared with BMS, regardless of the implantation sequences (85.7% in C+T vs. 14.3% in B+B vs. 71.4% in T+C, p=0.017). Notably, only the distal Cypher implantation group (C+T) had three cases of stent fracture. A histopathological analysis showed that despite similar arterial injury scores, Taxus and Cypher stents had higher inflammatory reactions at the overlapped and distal segments compared with those of BMS. Conclusion: Despite similar arterial injury, higher inflammatory reactions were observed in overlapping DES segments regardless of the implantation sequence compared with that of BMS. Moreover, DES was associated with impaired endothelial function on the adjacent nonstented segments.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN SOC CARDIOLOGY-
dc.subjectINTRAVASCULAR ULTRASOUND-
dc.subjectCLINICAL-OUTCOMES-
dc.subjectCORONARY-
dc.subjectINFLAMMATION-
dc.subjectIMPLANTATION-
dc.subjectRESTENOSIS-
dc.subjectTHROMBUS-
dc.subjectLESIONS-
dc.subjectSITES-
dc.titleImpact of Heterogeneous Overlapping Drug-Eluting Stents on the Arterial Responses of Rabbit Iliac Arteries: A Comparison With Overlapping Bare Metal Stents-
dc.typeArticle-
dc.contributor.affiliatedAuthorRha, Seung-Woon-
dc.contributor.affiliatedAuthorNa, Jin Oh-
dc.contributor.affiliatedAuthorChoi, Cheol Ung-
dc.contributor.affiliatedAuthorKim, Eung Ju-
dc.identifier.doi10.4070/kcj.2012.42.6.397-
dc.identifier.scopusid2-s2.0-84864002404-
dc.identifier.wosid000209080000005-
dc.identifier.bibliographicCitationKOREAN CIRCULATION JOURNAL, v.42, no.6, pp.397 - 405-
dc.relation.isPartOfKOREAN CIRCULATION JOURNAL-
dc.citation.titleKOREAN CIRCULATION JOURNAL-
dc.citation.volume42-
dc.citation.number6-
dc.citation.startPage397-
dc.citation.endPage405-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001671266-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.subject.keywordPlusINTRAVASCULAR ULTRASOUND-
dc.subject.keywordPlusCLINICAL-OUTCOMES-
dc.subject.keywordPlusCORONARY-
dc.subject.keywordPlusINFLAMMATION-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusRESTENOSIS-
dc.subject.keywordPlusTHROMBUS-
dc.subject.keywordPlusLESIONS-
dc.subject.keywordPlusSITES-
dc.subject.keywordAuthorDrug-eluting stents-
dc.subject.keywordAuthorEndothelium-
dc.subject.keywordAuthorVasoconstriction-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Cheol Ung photo

Choi, Cheol Ung
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE