- Kang, Jun Hyuk; Rha, Seung-Woon; Lee, Dae In; Kim, Sua; Lee, Jae Hyoung; Kang, Seung Hun; Lim, Sung Yoon; Choi, Byoung Geol; Elnagar, Amro; Kim, Sun Won; Im, Sung Il; Han, Seong Woo; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Jin Won; Kim, Eung Ju; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo
- Issue Date
- 3월-2012
- Publisher
- KOREAN SOC CARDIOLOGY
- Keywords
- Percutaneous transluminal coronary angioplasty; Complications
- Citation
- KOREAN CIRCULATION JOURNAL, v.42, no.3, pp.201 - 204
- Indexed
- SCOPUS
KCI
- Journal Title
- KOREAN CIRCULATION JOURNAL
- Volume
- 42
- Number
- 3
- Start Page
- 201
- End Page
- 204
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/108981
- DOI
- 10.4070/kcj.2012.42.3.201
- ISSN
- 1738-5520
- Abstract
- A 0.035-inch guide wire fracture and entrapment in a peripheral artery is a very rare complication, but when it does occur it may lead to life-threatening complications, such as perforation, thrombus formation, embolization, and subsequent limb ischemia. We describe our experience of successfully retrieving a fractured 0.035-inch Terumo guide wire in the external iliac artery using a biopsy forcep.