Comparison of Noise Power Spectrum Methodologies in Measurements by Using Megavoltage X-ray Energies
- Authors
- Min, Jung-Whan; Son, Jin-Hyun; Jeong, Hoi-Woun; Kim, Jung-Min; Seoung, Youl-Hun; Son, Soon-Yong; Kim, Ho-Kyung; Kim, Sang-Young; Lee, Do-Wan; Jung, Jae-Yong; Suh, Tae-Suk; Choe, Bo-Young
- Issue Date
- 1월-2012
- Publisher
- KOREAN PHYSICAL SOC
- Keywords
- Modulation transfer function (MTF); Noise power spectrum (NPS); Megavoltage X-ray imaging (MVI)
- Citation
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.60, no.1, pp.129 - 136
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY
- Volume
- 60
- Number
- 1
- Start Page
- 129
- End Page
- 136
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/109181
- DOI
- 10.3938/jkps.60.129
- ISSN
- 0374-4884
- Abstract
- The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electrotechnical Commission standard (IEC 62220-1). In order to measure the region of interest (ROI) of the NPS, we used the following five factors: the overlapping impact, the non-overlapping impact, the penumbra, the flatness and different ROI sizes. We used NPS from four different types of detectors, the CR-IP (computed radiography image plate: photo-stimulable phosphor screen), the CR-IP-lead (hexalon lead screen), the CR-IP-back [lanex TM fast back screen: {terbium-doped gadolinium oxysulfide granular phosphor screen (Gd2O2S: Tb, 133 mg/cm(2))} + 1-mm-thick copper plate] and the CR-IP-front (lanex TM fast front screen). A Kodak 2000 RT photo-stimulable phosphor-based computed radiographic (CR) system showed that the normalized noise power spectrum (NNPS) curve gradually decreased, in compliance with increasing spatial resolution. In addition, each detector showed a different reactivity of the NPS to megavoltage. The results of multivariate analysis of variance (MANOVA) test (methods x detectors) revealed significant main effects of the methods [F(1, 4) = 53.543, P = 0.001] and of the detectors [F(1, 4) = 17.556, P = 0.001]. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS control in MVI.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.