dc.description.abstractIn this study we have investigated a 2-dimensional gas type detector based on plasma display technology as a candidate for the flat-panel radiation detector. By using the Garfield code, the dependence of X-ray absorption and multiplication on gas composition, cell gap and electric field were examined. Considering the simulation results, three prototype detectors were designed and fabricated. The performance of these detectors was evaluated by measuring the collected charge density, dark current density and sensitivity. The collected charge had the highest value at a condition when Xe 100% and 2.8 mm gap was 108.8 nC/cm(2) at 1000 V. The dark current of the same detector was varied from 0.0095 to 0.10 nA/cm(2) and about a fourth of the dark current density of a-Se based detector was at the bias range of 100 - 1000 V. The sensitivity of Xe 100% and 2.8 mm detector was 0.20 nC/mR.cm(2) at 0.36 V/um. It is about a tenth lower than that of a-Se based detector at 10 V/um.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.subjectPANEL DETECTORS-
dc.titleFeasibility study of a plasma display-like radiation detector for X-ray imaging-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Kisung-
dc.identifier.doi10.3233/XST-2012-0335-
dc.identifier.scopusid2-s2.0-84866238889-
dc.identifier.wosid000308691500002-
dc.identifier.bibliographicCitationJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, v.20, no.3, pp.269 - 276-
dc.relation.isPartOfJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.titleJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.volume20-
dc.citation.number3-
dc.citation.startPage269-
dc.citation.endPage276-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusPANEL DETECTORS-
dc.subject.keywordAuthorRadiation detectors-
dc.subject.keywordAuthorgas-filled detectors-
dc.subject.keywordAuthorsensors-
dc.subject.keywordAuthorX-ray-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE