dc.description.abstract | The purpose of this study is to assess the extent and serial pattern of setup error of conventional fractionated whole pelvic irradiation using a kilovoltage on-board imager. The daily on-board images of 69 patients were matched with the digitally reconstructed radiographs of simulation on the basis of pelvic bony structure. The shifts along x- (lateral), y- (longitudinal), and z- (vertical) axes, and the 3D vector, were measured. The shift between an origin of the first fraction and each fraction (Delta shift(1st)) and the shift between an isocenter of simulation and each fraction (Delta shift(Sim)) were calculated. To evaluate serial changes, the shifts of each fraction were classified into four consecutive sessions, and an ANOVA and chi-square test were used. The systematic error of the Delta shift(Sim) and Delta shift(1st) were 2.72 and 1.43 mm along the x-axis, 2.98 and 1.28 mm along the y-axis, and 4.26 and 2.39 mm along the z-axis, respectively. The Delta shift(Sim) and Delta shift(1st) >= 5 mm of the 3D vector occurred in 54.3% and 23.1%, respectively. The recommended margins to cover setup error in case of using Delta shift(1st) were 3.81, 3.54, and 6.01 mm along x-, y-, and z- axes, whereas those using Delta shift(Sim) were 6.39, 6.95, and 9.95 mm, respectively. With the passage of time, the Delta shift(1st) >= 5 mm of 3D vector and along any axis in supine setup increased from 14.1% for first session to 22.5% for fourth session (p = 0.027) and from 10.8% to 18.5% (p = 0.034), respectively. In prone setup, first session was better than others in the Delta shift(1st) >= 5 mm of 3D vector and along any axis. It is expected that the correction using the on-board images on the first fraction improves geometrical uncertainties and reduces the margin for target coverage. Daily continuous OBI follow-up during conventional fractionated pelvic irradiation can increase the reproducibility and be more effective in the late period. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MULTIMED INC | - |
dc.subject | GYNECOLOGICAL MALIGNANCIES | - |
dc.subject | GEOMETRICAL UNCERTAINTIES | - |
dc.subject | RADIATION-THERAPY | - |
dc.subject | SETUP ERROR | - |
dc.subject | RADIOTHERAPY | - |
dc.subject | DEFINITION | - |
dc.subject | ACCURACY | - |
dc.subject | MARGINS | - |
dc.title | The extent and serial pattern of interfractional variation in patients with whole pelvic irradiation: a study using a kilovoltage orthogonal on-board imager | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Won Sup | - |
dc.contributor.affiliatedAuthor | Yang, Dae Sik | - |
dc.contributor.affiliatedAuthor | Lee, Suk | - |
dc.contributor.affiliatedAuthor | Kim, Chul Yong | - |
dc.identifier.doi | 10.1120/jacmp.v13i2.3636 | - |
dc.identifier.scopusid | 2-s2.0-84860725084 | - |
dc.identifier.wosid | 000304140300010 | - |
dc.identifier.bibliographicCitation | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, v.13, no.2, pp.92 - 102 | - |
dc.relation.isPartOf | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | - |
dc.citation.title | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | - |
dc.citation.volume | 13 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 92 | - |
dc.citation.endPage | 102 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | GYNECOLOGICAL MALIGNANCIES | - |
dc.subject.keywordPlus | GEOMETRICAL UNCERTAINTIES | - |
dc.subject.keywordPlus | RADIATION-THERAPY | - |
dc.subject.keywordPlus | SETUP ERROR | - |
dc.subject.keywordPlus | RADIOTHERAPY | - |
dc.subject.keywordPlus | DEFINITION | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordPlus | MARGINS | - |
dc.subject.keywordAuthor | interfractional variation | - |
dc.subject.keywordAuthor | on-board imagers | - |
dc.subject.keywordAuthor | pelvic irradiation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.