dc.description.abstract | The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. Lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 한국태양에너지학회 | - |
dc.title | 소규모 사무공간의 조명에너지 절감율 평가에 관한 연구 | - |
dc.title.alternative | Evaluation of Lighting Energy Saving Rate in a Small Office Space | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김강수 | - |
dc.identifier.bibliographicCitation | 한국태양에너지학회 논문집, v.32, no.3, pp.50 - 58 | - |
dc.relation.isPartOf | 한국태양에너지학회 논문집 | - |
dc.citation.title | 한국태양에너지학회 논문집 | - |
dc.citation.volume | 32 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 50 | - |
dc.citation.endPage | 58 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001673483 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | 데이심 | - |
dc.subject.keywordAuthor | 조명에너지 | - |
dc.subject.keywordAuthor | 조도측정 | - |
dc.subject.keywordAuthor | 절감율 | - |
dc.subject.keywordAuthor | 디밍제어 | - |
dc.subject.keywordAuthor | Daysim | - |
dc.subject.keywordAuthor | Lighting energy | - |
dc.subject.keywordAuthor | Illuminance measurement | - |
dc.subject.keywordAuthor | Saving rate | - |
dc.subject.keywordAuthor | Dimming Control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.