Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

주관절 척골신경병증에서 병변 국속화를 위한 신경전도검사

Full metadata record
DC Field Value Language
dc.contributor.author김봉주-
dc.contributor.author김동휘-
dc.contributor.author이지훈-
dc.contributor.author박병규-
dc.date.accessioned2021-09-07T01:11:08Z-
dc.date.available2021-09-07T01:11:08Z-
dc.date.created2021-06-17-
dc.date.issued2012-
dc.identifier.issn2733-6581-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/109760-
dc.description.abstractObjectives: To compare abductor digiti minimi (ADM) recording with first dorsal interosseous (FDI) recording for the localization of ulnar neuropathy at the elbow (UNE) with electrodiagnostic study and inching test. Methods: Eighty-seven hands with UNE were collected. Compound muscle action potentials were recorded from both ADM and FDI muscles and ulnar nerve was stimulated at the wrist, 3 cm distal and 7 cm proximal to the medial epicondyle. One cm short segment study of ulnar nerve was performed from 4cm distal to 3 cm proximal to the medial epicondyle by inching test. Results: UNE was diagnosed in 83 out of 87 hands with ADM recording and 84 out of 87 hands with FDI recording. Seven hands had nonconcordant abnormal findings along the recording site. In the inching test, 12 hands were not localized and 12 hands was localized with only one muscle recording. 48 hands showed same localization and 15 hands showed different localization with both ADM and FDI recordings. Conclusion: Since the result can differ according to the location of the recording electrode, motor conduction study and inching test of ulnar nerve should include recording from both ADM and FDI muscles.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한근전도전기진단의학회-
dc.title주관절 척골신경병증에서 병변 국속화를 위한 신경전도검사-
dc.title.alternativeUlnar Motor Nerve Conduction Study for Lesion Localization in Ulnar Neuropathy at Elbow-
dc.typeArticle-
dc.contributor.affiliatedAuthor김동휘-
dc.contributor.affiliatedAuthor박병규-
dc.identifier.doi10.18214/jkaem.2012.14.2.66-
dc.identifier.bibliographicCitation대한근전도 전기진단의학회지, v.14, no.2, pp.66 - 70-
dc.relation.isPartOf대한근전도 전기진단의학회지-
dc.citation.title대한근전도 전기진단의학회지-
dc.citation.volume14-
dc.citation.number2-
dc.citation.startPage66-
dc.citation.endPage70-
dc.type.rimsART-
dc.identifier.kciidART001719786-
dc.description.journalClass3-
dc.subject.keywordAuthorUlnar nerve-
dc.subject.keywordAuthorInching test-
dc.subject.keywordAuthorAbductor digiti minimi muscle-
dc.subject.keywordAuthorFirst dorsal interosseous muscle-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE