Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

허브 형상에 따른 정풍량 환기팬의 유동과 성능특성

Full metadata record
DC Field Value Language
dc.contributor.author이호호-
dc.contributor.author최항철-
dc.contributor.author정재구-
dc.contributor.author이윤표-
dc.contributor.author신유환-
dc.contributor.author정진택-
dc.date.accessioned2021-09-07T03:50:45Z-
dc.date.available2021-09-07T03:50:45Z-
dc.date.created2021-06-17-
dc.date.issued2012-
dc.identifier.issn2287-9706-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/110527-
dc.description.abstractThe constant air volume flow fan can maintain constant flow rate to the wide range of exit pressure. Therefore, the use of this fan is increasing recently for ventilation of high building. Brushless DC motor is adopted to this fan because that has advantages of compactness and performance. But this type of motor protrude from impeller hub side to fan inlet. The Impeller inlet flow is influenced by size of this obstacle called hub. In this paper, the influence of hub shape on the fan performance characteristics are experimentally and numerically analyzed. CFX 12.0 is used to perform the fan internal flow analysis and numerical results are compared with the experiments. Depending on hub shape, internal loss is generated and the performance and efficiency are reduced. The best performance is occurred around h/b1 = 0.25. The results of this study will be contribute to initial design of constant air volume flow fan development.-
dc.languageKorean-
dc.language.isoko-
dc.publisher한국유체기계학회-
dc.title허브 형상에 따른 정풍량 환기팬의 유동과 성능특성-
dc.title.alternativeFlow Behavior and Performance Characteristics of Constant Air Volume Fan According to Different Hub Shape-
dc.typeArticle-
dc.contributor.affiliatedAuthor정진택-
dc.identifier.bibliographicCitation한국유체기계학회 논문집, v.15, no.2, pp.57 - 62-
dc.relation.isPartOf한국유체기계학회 논문집-
dc.citation.title한국유체기계학회 논문집-
dc.citation.volume15-
dc.citation.number2-
dc.citation.startPage57-
dc.citation.endPage62-
dc.type.rimsART-
dc.identifier.kciidART001648951-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorConstant air volume flow fan(정풍량 팬)-
dc.subject.keywordAuthorFlow behavior(유체거동)-
dc.subject.keywordAuthorHub shape(허브형상)-
dc.subject.keywordAuthorPerformance test(성능실험)-
dc.subject.keywordAuthorNumerical analysis(전산해석)-
dc.subject.keywordAuthorEfficiency(효율)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHUNG, Jin Taek photo

CHUNG, Jin Taek
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE