Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Persistent perceptual delay for head movement onset relative to auditory stimuli of different durations and rise times

Full metadata record
DC Field Value Language
dc.contributor.authorBarnett-Cowan, M.-
dc.contributor.authorRaeder, S.M.-
dc.contributor.authorBülthoff, H.H.-
dc.date.accessioned2021-09-07T04:00:51Z-
dc.date.available2021-09-07T04:00:51Z-
dc.date.created2021-06-17-
dc.date.issued2012-
dc.identifier.issn0014-4819-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/110595-
dc.description.abstractThe perception of simultaneity between auditory and vestibular information is crucially important for maintaining a coherent representation of the acoustic environment whenever the head moves. It has been recently reported, however, that despite having similar transduction latencies, vestibular stimuli are perceived significantly later than auditory stimuli when simultaneously generated. This suggests that perceptual latency of a head movement is longer than a co-occurring sound. However, these studies paired a vestibular stimulation of long duration (~1 s) and of a continuously changing temporal envelope with a brief (10-50 ms) sound pulse. In the present study, the stimuli were matched for temporal envelope duration and shape. Participants judged the temporal order of the two stimuli, the onset of an active head movement and the onset of brief (50 ms) or long (1,400 ms) sounds with a square- or raised-cosine-shaped envelope. Consistent with previous reports, head movement onset had to precede the onset of a brief sound by about 73 ms in order for the stimuli to be perceived as simultaneous. Head movements paired with long square sounds (~100 ms) were not significantly different than brief sounds. Surprisingly, head movements paired with long raised-cosine sound (~115 ms) had to be presented even earlier than brief stimuli. This additional lead time could not be accounted for by differences in the comparison stimulus characteristics (temporal envelope duration and shape). Rather, differences between sound conditions were found to be attributable to variability in the time for head movement to reach peak velocity: the head moved faster when paired with a brief sound. The persistent lead time required for vestibular stimulation provides further evidence that the perceptual latency of vestibular stimulation is greater than the other senses. © 2012 The Author(s).-
dc.languageEnglish-
dc.language.isoen-
dc.subjectacoustics-
dc.subjectadult-
dc.subjectarticle-
dc.subjectauditory stimulation-
dc.subjectfemale-
dc.subjecthead movement-
dc.subjecthuman-
dc.subjecthuman experiment-
dc.subjectlatent period-
dc.subjectmale-
dc.subjectperception disorder-
dc.subjectpriority journal-
dc.subjectsound-
dc.subjectstimulus response-
dc.subjectvelocity-
dc.subjectvestibular stimulation-
dc.subjectAcoustic Stimulation-
dc.subjectAdult-
dc.subjectAuditory Perception-
dc.subjectFemale-
dc.subjectHead Movements-
dc.subjectHumans-
dc.subjectMale-
dc.subjectMiddle Aged-
dc.subjectPsychoacoustics-
dc.subjectReaction Time-
dc.subjectSignal Detection, Psychological-
dc.subjectTime Factors-
dc.subjectYoung Adult-
dc.titlePersistent perceptual delay for head movement onset relative to auditory stimuli of different durations and rise times-
dc.typeArticle-
dc.contributor.affiliatedAuthorBülthoff, H.H.-
dc.identifier.doi10.1007/s00221-012-3112-x-
dc.identifier.scopusid2-s2.0-84862775522-
dc.identifier.bibliographicCitationExperimental Brain Research, v.220, no.1, pp.41 - 50-
dc.relation.isPartOfExperimental Brain Research-
dc.citation.titleExperimental Brain Research-
dc.citation.volume220-
dc.citation.number1-
dc.citation.startPage41-
dc.citation.endPage50-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusacoustics-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusarticle-
dc.subject.keywordPlusauditory stimulation-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlushead movement-
dc.subject.keywordPlushuman-
dc.subject.keywordPlushuman experiment-
dc.subject.keywordPluslatent period-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusperception disorder-
dc.subject.keywordPluspriority journal-
dc.subject.keywordPlussound-
dc.subject.keywordPlusstimulus response-
dc.subject.keywordPlusvelocity-
dc.subject.keywordPlusvestibular stimulation-
dc.subject.keywordPlusAcoustic Stimulation-
dc.subject.keywordPlusAdult-
dc.subject.keywordPlusAuditory Perception-
dc.subject.keywordPlusFemale-
dc.subject.keywordPlusHead Movements-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusMale-
dc.subject.keywordPlusMiddle Aged-
dc.subject.keywordPlusPsychoacoustics-
dc.subject.keywordPlusReaction Time-
dc.subject.keywordPlusSignal Detection, Psychological-
dc.subject.keywordPlusTime Factors-
dc.subject.keywordPlusYoung Adult-
dc.subject.keywordAuthorAuditory-
dc.subject.keywordAuthorDuration-
dc.subject.keywordAuthorHead movement-
dc.subject.keywordAuthorMultisensory-
dc.subject.keywordAuthorSubjective simultaneity-
dc.subject.keywordAuthorTemporal order judgment-
dc.subject.keywordAuthorTime perception-
dc.subject.keywordAuthorVestibular-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Brain and Cognitive Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE