Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of the clinical effectiveness between the streamlined liner of pharyngeal airway (SLIPA) and the laryngeal mask airway by novice personnel

Full metadata record
DC Field Value Language
dc.contributor.authorOh, S.-K.-
dc.contributor.authorLim, B.G.-
dc.contributor.authorKim, H.-
dc.contributor.authorLim, S.H.-
dc.date.accessioned2021-09-07T04:01:22Z-
dc.date.available2021-09-07T04:01:22Z-
dc.date.created2021-06-17-
dc.date.issued2012-
dc.identifier.issn2005-6419-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/110598-
dc.description.abstractBackground: The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA) with the classic laryngeal mask airway when used by novice personnel. Methods: There were 114 patients enrolled into this study who underwent general anesthesia were randomly allocated into one of 2 groups; LMA group (n = 57) or SLIPA group (n = 57). After insertion, insertion success rate, insertion time, and hemodynamic responses to insertion were accessed. After surgery, postoperative airway morbidity (sore throat, dysphonia, dysphagia) were evaluated. Results: The SLIPA was successfully inserted in 96% of patients (55/57) and the LMA in 93% (53/57) (P = 0.408). First attempt success rates were 88% (44/57) and 77% (50/57) in the SLIPA and the LMA (P = 0.142). The successful insertion time in SLIPA group (33.4 ± 11.0 sec) was significantly shorter than that of LMA group (38.8 ± 16.6 sec) (P = 0.048) and the insertion time at the first attempt was also shorter in SLIPA group (31.0 ± 6.3 sec) than LMA group (34.7 ± 8.6 sec) (P = 0.013). There was no statistically significant difference between the two groups in hemodynamic responses and postoperative airway morbidity. Conclusions: The SLIPA was similar to the LMA in insertion success rate, hemodynamic response, and postoperative airway morbidity by novice personnel. The insertion time at the first attempt and successful insertion time of the SLIPA were significantly shorter than those of the LMA. Therefore, the SLIPA could be a useful alternative to the LMA as primary SGA for novice personnel. (Korean J Anesthesiol 2012; 63: 136-141).© the Korean Society of Anesthesiologists, 2012.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKorean Society of Anesthesiologists-
dc.subjectadult-
dc.subjectairway-
dc.subjectanesthetic equipment-
dc.subjectarticle-
dc.subjectclinical effectiveness-
dc.subjectcontrolled study-
dc.subjectdysphagia-
dc.subjectdysphonia-
dc.subjectfemale-
dc.subjectgeneral anesthesia-
dc.subjecthuman-
dc.subjectintermethod comparison-
dc.subjectlaryngeal mask-
dc.subjectlung hemodynamics-
dc.subjectmajor clinical study-
dc.subjectmale-
dc.subjectmedical personnel-
dc.subjectmorbidity-
dc.subjectpostoperative period-
dc.subjectsore throat-
dc.subjectstatistical significance-
dc.subjectstreamlined liner of pharyngeal airway-
dc.titleComparison of the clinical effectiveness between the streamlined liner of pharyngeal airway (SLIPA) and the laryngeal mask airway by novice personnel-
dc.typeArticle-
dc.contributor.affiliatedAuthorLim, B.G.-
dc.contributor.affiliatedAuthorKim, H.-
dc.contributor.affiliatedAuthorLim, S.H.-
dc.identifier.doi10.4097/kjae.2012.63.2.136-
dc.identifier.scopusid2-s2.0-84930477627-
dc.identifier.bibliographicCitationKorean Journal of Anesthesiology, v.63, no.2, pp.136 - 141-
dc.relation.isPartOfKorean Journal of Anesthesiology-
dc.citation.titleKorean Journal of Anesthesiology-
dc.citation.volume63-
dc.citation.number2-
dc.citation.startPage136-
dc.citation.endPage141-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001687703-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusairway-
dc.subject.keywordPlusanesthetic equipment-
dc.subject.keywordPlusarticle-
dc.subject.keywordPlusclinical effectiveness-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusdysphagia-
dc.subject.keywordPlusdysphonia-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlusgeneral anesthesia-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusintermethod comparison-
dc.subject.keywordPluslaryngeal mask-
dc.subject.keywordPluslung hemodynamics-
dc.subject.keywordPlusmajor clinical study-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmedical personnel-
dc.subject.keywordPlusmorbidity-
dc.subject.keywordPluspostoperative period-
dc.subject.keywordPlussore throat-
dc.subject.keywordPlusstatistical significance-
dc.subject.keywordPlusstreamlined liner of pharyngeal airway-
dc.subject.keywordAuthorAirway-
dc.subject.keywordAuthorLaryngeal mask-
dc.subject.keywordAuthorSLIPA-
dc.subject.keywordAuthorSupraglottic-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hee Zoo photo

Kim, Hee Zoo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE